APAR status
Closed as program error.
Error description
Error Message: Various, depending on the application . Stack Trace: .
Local fix
Problem summary
OpenJ9 v0.51.0 introduced an unexpected change to the contents of the os.version system property for Semeru 21 on z/OS. This was due to an unintentional change in the z/OS API used by the OpenJ9 JVM to obtain the operating system version information. The __osname() API was used before the change, switching to uname() after the change. For example, with Semeru 21.0.6.0 on z/OS 3.1, the os.version property's value was: 03.01.00 But with 21.0.7.0 it changed to: 29.00 This may cause problems for applications which rely on the format of the version string.
Problem conclusion
OpenJ9 has reverted back to using __osname() to populate the os.version system property, thus restoring the original behaviour . This APAR will be fixed in the following Releases: . IBM Semeru Runtimes 21 21.0.8.0 . Downloads and supplementary documentation can be found at the following locations: - For non z/OS operating systems: - IBM Semeru Runtimes, Version 11 and later https://www.ibm.com/semeru-runtimes/downloads/ - IBM SDK, Java Technology Edition, Version 8 https://www.ibm.com/support/pages/java-sdk-downloads/ - For the z/OS operating system: - Java SDK Products on z/OS https://www.ibm.com/support/pages/java-sdk-products-zos
Temporary fix
Comments
APAR Information
APAR number
IJ55286
Reported component name
J9 COMMON CODE
Reported component ID
620700127
Reported release
290
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-07-16
Closed date
2025-07-16
Last modified date
2025-07-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
J9 COMMON CODE
Fixed component ID
620700127
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information