APAR status
Closed as program error.
Error description
The system may crash with the following stack if extended attribute (eav1) value is corrupted. CRASH INFORMATION: CPU 0 CSA F00000002FF47600 at time of crash, error code for LEDs: 70000000 pvthread+0CB400 STACK: [00379A28]dbUpdatePMap+0000C8 (F1000C0035A97D00, F1000C02A0523080, 00000000003FFFFF, F1000C0EE0AD6000, F1000C0EE02F1430 [??]) [0039F798]txFreeMap+000398 (??, ??, ??, ??) [0039D8D4]IPRA.$txUpdateMap+000134 (??, ??) [003A0CBC]txCommit+0007BC (??, ??, ??, ??) [003F0C40]j2_remove+0004A0 (??, ??, ??, ??) [0075369C]vnop_remove+00047C (??, ??, ??, ??) [0086546C]kunlinkat+00056C (FFFFFFFEFFFFFFFE, 00000001100ADBD0, 000000011008AE10, 0000000000000000) [0000394C]syscall+000244 () [kdb_get_virtual_memory] no real storage @ 2FF22588 [10000E60]10000E60 () [kdb_read_mem] no real storage @ FFFFFFFFFFF5C60
Local fix
No local fix but is rarely seen.
Problem summary
system crash may happen if a file with acl attributes under JFS2 gets deleted.
Problem conclusion
To prevent the crash, if inconsistency is detected in the internal data-structures of inode, mark the inode as corrupt and accordingly mark the filesystem for repair.
Temporary fix
Comments
7300-04 - use AIX APAR IJ55194
APAR Information
APAR number
IJ55194
Reported component name
AIX V7.3
Reported component ID
5765CD300
Reported release
730
Status
CLOSED PER
HIPER
NoHIPER
Submitted date
2025-07-08
Closed date
2025-07-08
Last modified date
2025-12-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.3
Fixed component ID
5765CD300
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11T","label":"AIX 7.3 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"730","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]