IBM Support

IJ53686: SNAP SVCOLLECT GENERATES PERMISSION DENIED IN SVCOLLECT.ERR

 

APAR status

  • Closed as program error.

Error description

  • Running snap svCollect (oem_setup_env or padmin)in VIOS
    4.1, generates
    Permission Denied within File svCollect.err from snap
    collection
    logs in SvCollect.
    
    could not change directory to "/home/padmin": Permission
    denied
    

Local fix

  • n/a
    

Problem summary

  • Running snap on VIOS 4.1 generates errors in svCollect.err
    

Problem conclusion

  • Correct the way we call some database collection programs so
    that errors are not generated
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ53686

  • Reported component name

    AIX V7.3

  • Reported component ID

    5765CD300

  • Reported release

    730

  • Status

    CLOSED PER

  • HIPER

    NoHIPER

  • Submitted date

    2025-02-24

  • Closed date

    2025-02-24

  • Last modified date

    2025-02-24

  • APAR is sysrouted FROM one or more of the following:

    IJ53471

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.3

  • Fixed component ID

    5765CD300

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11T","label":"AIX 7.3 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"730","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]