Error description

  • **************************************************************
    * USERS AFFECTED:
    * Systems running the AIX 7200-05-08 Technology Level
    * or VIOS 3.1.4.4x with any of the following filesets
    * at or between the given levels:
    * MIN          MAX          FILESET
    * 7.2.5.202    7.2.5.202    devices.ethernet.mlx.rte
      **************************************************************
    * ERROR DESCRIPTION:
    * Some 10GbE/40GbE RoCE adapters will not configure on the
    * following levels of AIX and VIOS:
    *
    * AIX 7200-05-08
    * AIX 7300-02-02
    * VIOS 3.1.4.40/3.1.4.41
    * VIOS 4.1.0.20/4.1.0.21
    *
    * The device driver cannot be loaded and the devices will
    * remain unusable in a "defined" state, resulting in loss of
    * network connectivity to the LPAR.  For a VIOS LPAR, this
    * can affect client LPARs with virtualized connections that
    * use this adapter as well.
    *
    * The following adapters are affected (feature code followed
    * by description):
    * EC27 PCIe2 2-Port 10GbE RoCE SFP+ Adapter LP
    * EC28 PCIe2 2-Port 10GbE RoCE SFP+ Adapter
    * EC29 PCIe2 2-Port 10GbE RoCE SR Adapter LP
    * EC30 PCIe2 2-Port 10GbE RoCE SR Adapter
    * EC37 2-PORT 10GbE EN/RoCE PCIe 3.0 LP X8 ADAPTER
    * EL3X 2-PORT 10GbE EN/RoCE PCIe 3.0 LP X8 ADAPTER
    * EC38 2-PORT 10GbE EN/RoCE PCIe 3.0 LP CAPABLE X8 ADAPTER
    * EC2M 2-PORT 10GbE EN/RoCE PCIe 3.0 LP X8 ADAPTER W/OPTICS
    * EL40 2-PORT 10GbE EN/RoCE PCIe 3.0 LP X8 ADAPTER W/OPTICS
    * EC2N 2-PORT 10GbE EN/RoCE PCIe 3.0 LP CAPABLE X8 ADAPTER
    * W/OPTICS
    * EC3A 2-PORT 40GbE RoCE SFP+ PCIe 3.0 LP ADAPTER
    * EC3B 2-PORT 40GbE RoCE SFP+ PCIe 3.0 LP CAPABLE
    * EL27 (RP #EC27) 2-PORT 10GbE RoCE SFP+ LP ADAPTER
    *
    * Use "How to determine Feature Code"
    * (https://www.ibm.com/support/pages/how-find-feature-code-
    * aix-linux-ibm-i-adapters-and-going-fix-central-look-fixes)
    * to help determine if you have an affected adapter.
    *
    * Prior to updating to one of the levels above, if the
    * affected adapters are used, care must be taken to apply an
    * ifix for this issue prior to booting on the updated SP or
    * else there may be no network connectivity available to the
    * LPAR after booting.
    *
    * For normal AIX updates and VIOS updateios, the ifix can be
    * applied to the LPAR after the SP is applied, before rebooting.
    * For nim installs, the ifix can be applied to the update spot
    * resource by following the steps HERE
    * (https://www.ibm.com/docs/en/aix/7.3?topic=resources-
    * installing-interim-fix-into-spot-resource).
    * For alt_disk installs, the ifix can be applied to the
    * upgraded alt_disk image by following step 3 HERE
    * (https://www.ibm.com/support/pages/managing-multiple-
    * instances-altinstrootvg-and-applying-fixes-them).
    * For viosupgrade, first upgrade to 4.1.0.10 using viosupgrade
    * (making sure the fix for HIPER IJ50326
    * (https://www.ibm.com/support/pages/node/7145269) is in place
    * first).  After completing that upgrade, then apply
    * 4.1.0.21 SP + ifix at the same time using updateios.
      **************************************************************
    * RECOMMENDATION:
    * Install APAR IJ51639.
    * Prior to fix availability, an interim fix is available from
    * either
    * ftp://aix.software.ibm.com/aix/ifixes/ij51639/
    * https://aix.software.ibm.com/aix/ifixes/ij51639/
    * The ifix can be installed using Live Update (LU).
    * If LU is not used, installation of the ifix requires a
    * reboot.
      **************************************************************
    

Local fix

  • LOCAL FIX:
    PROBLEM SUMMARY:
    Some 10GbE/40GbE RoCE adapters will not configure on the
    following levels of AIX and VIOS:
    

Problem summary

  • LOCAL FIX:
    PROBLEM SUMMARY:
    Some 10GbE/40GbE RoCE adapters will not configure on the
    following levels of AIX and VIOS:
    

Problem conclusion

  • Fixed the issue of device getting stopped and made it
    available
    

Temporary fix

Comments

  • 7200-05 - use AIX APAR IJ51639
    7300-03 - use AIX APAR IJ51859
    

APAR Information

  • APAR number

    IJ51639

  • Reported component name

    AIX V7.3

  • Reported component ID

    5765CD300

  • Reported release

    720

  • Status

    CLOSED PER

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-06-26

  • Closed date

    2024-08-12

  • Last modified date

    2025-02-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IJ51842 IJ51859 IJ51895

Fix information

  • Fixed component name

    AIX V7.2

  • Fixed component ID

    5765CD200

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11S","label":"AIX 7.2 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date:
08 February 2025