APAR status
Closed as program error.
Error description
SED Enabled NVMe drives cannot boot AIX as Admin PIN is used as PKS primary by PFW, which results in AIX nvme driver failing to unlock the drive.
Local fix
Problem summary
SED Enabled NVMe drives cannot boot AIX as Admin PIN is used as PKS primary by PFW, which results in AIX nvme driver failing to unlock the drive.
Problem conclusion
AIX nvme driver retries to unlock the drive using Admin's authority if using User authority fails during drive unlocking.
Temporary fix
Comments
7200-05 - use AIX APAR IJ51575 7300-03 - use AIX APAR IJ51224
APAR Information
APAR number
IJ51224
Reported component name
AIX V7.3
Reported component ID
5765CD300
Reported release
730
Status
CLOSED PER
HIPER
NoHIPER
Submitted date
2024-05-17
Closed date
2024-05-17
Last modified date
2025-02-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.3
Fixed component ID
5765CD300
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11T","label":"AIX 7.3 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"730","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information