APAR status
Closed as program error.
Error description
Failure of the viosupgrade process occurred because of an incorrect use of the mkvg -a option during the execution of alt_disk_mksysb
Local fix
Problem summary
Failure of the viosupgrade process occurred because of an incorrect use of the mkvg -a option during the execution of alt_disk_mksysb
Problem conclusion
The viosupgrade process failed due to an incorrect utilization of the mkvg -a option while executing alt_disk_mksysb.mkvg -a option or crfs logname=OUTLINE was introduced in version 7.3 and is not available in previous versions.keep oslevel check while adding -a option to mkvg and logname=OUTLINE to crfs
Temporary fix
Comments
APAR Information
APAR number
IJ50614
Reported component name
AIX V7.3
Reported component ID
5765CD300
Reported release
730
Status
CLOSED PER
HIPER
NoHIPER
Submitted date
2024-03-25
Closed date
2024-03-25
Last modified date
2024-12-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.3
Fixed component ID
5765CD300
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11T","label":"AIX 7.3 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"730","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information
Modified date: