IBM Support

IJ50568: VIOS UPGRADE FAILS BETWEEN MAJOR VIOS VERSIONS APPLIES TO AIX 7300-02

 

APAR status

  • Closed as program error.

Error description

  • Failure of the viosupgrade process occurred because of an
    incorrect use of the mkvg -a option during the execution of
    alt_disk_mksysb
    

Local fix

Problem summary

  • Failure of the viosupgrade process occurred because of an
    incorrect use of the mkvg -a option during the execution of
    alt_disk_mksysb
    

Problem conclusion

  • The viosupgrade process failed due to an incorrect utilization
    of the mkvg -a option while executing alt_disk_mksysb.mkvg -a
    option or crfs logname=OUTLINE was introduced in version 7.3
    and is not available in previous versions.keep oslevel check
    while adding -a option to mkvg and logname=OUTLINE to crfs
    

Temporary fix

Comments

  • 7300-02 - use AIX APAR IJ50568
    

APAR Information

  • APAR number

    IJ50568

  • Reported component name

    AIX V7.3

  • Reported component ID

    5765CD300

  • Reported release

    730

  • Status

    CLOSED PER

  • HIPER

    NoHIPER

  • Submitted date

    2024-03-21

  • Closed date

    2024-03-21

  • Last modified date

    2025-10-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IJ50591 IJ50614 IJ56407

Fix information

  • Fixed component name

    AIX V7.3

  • Fixed component ID

    5765CD300