APAR status
Closed as program error.
Error description
Failure of the viosupgrade process occurred because of an incorrect use of the mkvg -a option during the execution of alt_disk_mksysb
Local fix
Problem summary
Failure of the viosupgrade process occurred because of an incorrect use of the mkvg -a option during the execution of alt_disk_mksysb
Problem conclusion
The viosupgrade process failed due to an incorrect utilization of the mkvg -a option while executing alt_disk_mksysb.mkvg -a option or crfs logname=OUTLINE was introduced in version 7.3 and is not available in previous versions.keep oslevel check while adding -a option to mkvg and logname=OUTLINE to crfs
Temporary fix
Comments
7300-02 - use AIX APAR IJ50568
APAR Information
APAR number
IJ50568
Reported component name
AIX V7.3
Reported component ID
5765CD300
Reported release
730
Status
CLOSED PER
HIPER
NoHIPER
Submitted date
2024-03-21
Closed date
2024-03-21
Last modified date
2025-10-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.3
Fixed component ID
5765CD300
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11T","label":"AIX 7.3 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"730","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information
Modified date:
11 October 2025