APAR status
Closed as program error.
Error description
Problem Description Self-reference object structure creates duplicate records when it has child tables STEPS TO REPRODUCE: The steps below use MAXDEMO as an example: 1)Go to Object Structure application and duplicate MXWOHIER object. Create a new Object with name MXWOHPF. Include the table WPTOOL and use the relationship WPTOOL. 2)Create a new Enterprise Service MXWOHPF and use the Object Structure MXWOHPF. 3)Assign and enable the Enterprise Service MXWOHPF into the External System EXTSYS1 4)Import the XML below: <?xml version="1.0" encoding="UTF-8"?> <SyncMXWOHPF xmlns="http://www.ibm.com/maximo" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" creationDateTime="2023-03- 01T03:49:05-05:00" transLanguage="EN" baseLanguage="EN" messageID="1141816776605462396544"> <MXWOHPFSet> <WORKORDER action="AddChange"> <WONUM>F100374-01</WONUM> <SITEID>BEDFORD</SITEID> <DESCRIPTION>CMPWO</DESCRIPTION> <WPTOOL> <ITEMNUM>FORK</ITEMNUM> <ITEMQTY>1.0</ITEMQTY> </WPTOOL> </WORKORDER> </MXWOHPFSet> </SyncMXWOHPF> RESULTS: Wptool will be created twice in the Workorder F100374-01. The Workorder is processed twice. Observation: If wonum is restricted Work Order is created twice and each with one tool. EXPECTED RESULTS: Workorder should proceed once. REPORTED IN VERSION: Tivoli's process automation engine 7.6.1.3
Local fix
NA
Problem summary
**************************************************************** * USERS AFFECTED: * * _MAXIMO_ * **************************************************************** * PROBLEM DESCRIPTION: * * SELF-REFERENCE OBJECT STRUCTURE CREATES DUPLICATE RECORDS * * WHEN IT HAS CHILD TABLES * ****************************************************************
Problem conclusion
the fix for this APAR is contained in the future maintenance package.
Temporary fix
Comments
APAR Information
APAR number
IJ50318
Reported component name
INTEGRATION
Reported component ID
5724R46I1
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-02-29
Closed date
2024-03-04
Last modified date
2024-03-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
_MAXIMO_
Fix information
Fixed component name
INTEGRATION
Fixed component ID
5724R46I1
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
04 April 2024