APAR status
Closed as program error.
Error description
DSI crash (19)> f pvthread+0A7000 STACK: [F10009159029F224]npiv_real_fcscsi_async+000024 (700DFEED00007262, F1000915606004A0, 0000000000000000 [??]) [00014D70].hkey_legacy_gate+00004C () [0777251C]emfsc_npiv_send_async_stat+0000DC (??, ??, ??, ??, ??, ??, ??, ??) [07772B58]emfsc_npiv_async_stat+000498 (??, ??, ??, ??) [0773BB34]emfsc_async_rscn+000614 (??, ??) [0773F258]emfsc_async_stat+000478 (??, ??, ??) [07541238]emfc_async_status@AF105_1+000078 (??, ??, ??) [0752D4F0]emfc_async_status+000050 (??, ??) [07531188]emfc_offlevel_admin_completion+000828 (??) [0017A08C]IPRA.$i_offlevel+0000AC (??, ??) [00179A08]i_softmod+0005C8 ()
Local fix
Problem summary
When vfc host adapter is unconfigured while async events are underway from fabric, the FC protocol appears to send an async event for a vfchost adapter that has already been removed.
Problem conclusion
Serialization added between unconfig path and async event notification path in VFC host driver.
Temporary fix
Comments
7200-05 - use AIX APAR IJ49206 7300-02 - use AIX APAR IJ49486
APAR Information
APAR number
IJ49486
Reported component name
AIX V7.3
Reported component ID
5765CD300
Reported release
730
Status
CLOSED PER
HIPER
NoHIPER
Submitted date
2023-12-11
Closed date
2023-12-11
Last modified date
2024-12-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.3
Fixed component ID
5765CD300
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11T","label":"AIX 7.3 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"730","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information
Modified date:
13 December 2024