APAR status
Closed as program error.
Error description
Shutdown hangs if console redirected to a file on a filesystem mounted over a second filesystem.
Local fix
A workaround would be to switch the console back to the original tty ie: swcons before issuing a shutdown command. Another workaround, even after it hangs is to open a console window at the HMC that will allow the shutdown to continue.
Problem summary
SHUTDOWN HANGS WHEN CONSOLE REDIRECTED TO A FILE
Problem conclusion
Corrected the shutdown command to avoid hang when console redirected to a file.
Temporary fix
Comments
7200-05 - use AIX APAR IJ46893 7300-02 - use AIX APAR IJ46512
APAR Information
APAR number
IJ46893
Reported component name
AIX V7.2
Reported component ID
5765CD200
Reported release
720
Status
CLOSED PER
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-05-19
Closed date
2023-05-19
Last modified date
2024-01-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.2
Fixed component ID
5765CD200
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11S","label":"AIX 7.2 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information
Modified date:
12 January 2024