Error description

  • Unable to customize the caa.debug line in syslog.conf.
    For example:
        1-) Change the following line:
             caa.debug    /var/adm/ras/syslog.caa
        2-) reboot the system and and additional caa.debug
    line will be added
             to the /etc/syslog.conf file.
             ===
             caa.debug    /var/adm/ras/syslog.caa
             caa.debug /var/adm/ras/syslog.caa rotate size
    10m files 10 compress
             ====
    

Local fix

  • Adding a trailing space after /var/adm/ras/syslog.caa.
    

Problem summary

  • A trailing space following the caa.debug line in the
    syslog.conf file causes the default value to be appended to the
    file and used instead of the user modified line.
    

Problem conclusion

  • Trailing spaces are now allowed for the caa.debug line of the
    syslog.conf file.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ46098

  • Reported component name

    AIX V7.2

  • Reported component ID

    5765CD200

  • Reported release

    720

  • Status

    CLOSED PER

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-03-22

  • Closed date

    2023-03-22

  • Last modified date

    2023-11-13

  • APAR is sysrouted FROM one or more of the following:

    IJ45062

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.2

  • Fixed component ID

    5765CD200

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11S","label":"AIX 7.2 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date:
14 November 2023