Error description

  • ERROR DESCRIPTION:
    When integrity checker runs in repair mode, and when fixing
    woancestor, it tries to commit, however, the connection passed
    to the process has auto-commit already set, which causes the
    following exception:
    BMXAA0443E -- Error - BMXAA6247E -- Ancestor table WOANCESTOR
    has bad data. Run Integrity Checker in repair mode to fix this
    data. Wed Jul 20 08:48:04 MST 2022
    Could not commit with auto-commit set on
    	at
    oracle.jdbc.driver.PhysicalConnection(PhysicalConnection.java:
    2171)
    	at
    oracle.jdbc.driver.PhysicalConnection(PhysicalConnection.java:
    2207)
    
    ENVIRONMENT
    Tivoli's process automation engine 7.6.1.2-IFIX20220506-1004
    Build 20200715-0100 DB Build V7612-284 HFDB Build HF7612-119
    Server DB: Oracle 19.0 (Oracle Database 19c Enterprise Edition
    Release 19.0.0.0.0 - Production Version 19.14.0.0.0)
    

Local fix

Problem summary

  • ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * INTEGRITY CHECKER IN REPAIR MODE PRODUCES EXCEPTION DUE TO   *
    * AUTO-COMMIT                                                  *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is contained in the future release
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ41708

  • Reported component name

    MAXIMO SYSTEMS

  • Reported component ID

    5724R46AV

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-08-10

  • Closed date

    2024-06-25

  • Last modified date

    2024-06-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • MAXIMO
    

Fix information

  • Fixed component name

    MAXIMO SYSTEMS

  • Fixed component ID

    5724R46AV

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
25 June 2024