IBM Support

IJ41024: ERROR "BMXAA2256E - FIELD 'SAME AS OBJECT' IS READ-ONLY" WHEN TRYING TO ADD A VALUE IN THE "SAME AS OBJECT" FIELD

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Problem description:
    
    In Maximo database configuration the "sameasobject" and
    "sameasattribute" are read only and blank for the Oil & Gas
    "PLUSGRELATEDREC" object with its "RELATEDRECWONUM" attribute.
    
    When changing the "wonum" attribute in "workorder" object, this
    change does not propagate into this object.
    
    Steps to reproduce:
    
    1. Go to Database configuration
    2. Search for PLUSGRELATEDREC object
    3. Go to Attributes tab and search for RELATEDRECWONUM attribute
    
    4. Expand this attribute and go to Same as Object field
    5. Attempt to add an object, e.g WORKORDER
    
    Current results:
    
    A pop-up message appears: BMXAA2256E - Field Same as Object is
    read-only.
    
    Expected results:
    Having SAMEASOBJECT="WORKORDER" and SAMEASATTRIBUTE="WONUM" for
    PLUSGRELATEDREC.relatedrecwonum field.
    
    
    
    Tivoli's process automation engine 7.6.1.2
    IBM Maximo for Oil And Gas 7.6.2.0
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * OIL                                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Error "BMXAA2256E - field 'same as object' is read-only"     *
    * when trying to add a value in the "same as object" field     *
    ****************************************************************
    

Problem conclusion

  • A fix was created to set same as object (workorder) and same as
    attribute (wonum).
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ41024

  • Reported component name

    MAXIMO OIL & GA

  • Reported component ID

    5724R5400

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-07-06

  • Closed date

    2022-07-09

  • Last modified date

    2022-09-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following: