Error description

  • clmgr q app <app_name> command is listing 2 entries for one
    application while querying application.
    1. With Single App:
    (0) root @ r3r1m1p07: /
    clmgr q app
    app_con1
    (0) root @ r3r1m1p07: /
    clmgr q app app_con1
    NAME="app_con1"
    ASSOCIATEDMONITORS=""
    MONITORS="app_mon1"
    STARTSCRIPT="/home/scripts/APP_START.sh"
    STOPSCRIPT="/home/scripts/APP_STOP.sh"
    CPU_USAGE_MONITOR="no"
    PROCESS_TO_MONITOR_CPU_USAGE=""
    CPU_USAGE_MONITOR_INTERVAL="10"
    RESOURCE_GROUP=""
    MONITORING_STATUS=""
    RAW_MONITORING_STATUS=""
    STARTUP_MODE="background"
    NAME=""
    ASSOCIATEDMONITORS=""
    MONITORS=""
    STARTSCRIPT=""
    STOPSCRIPT=""
    CPU_USAGE_MONITOR=""
    PROCESS_TO_MONITOR_CPU_USAGE=""
    CPU_USAGE_MONITOR_INTERVAL=""
    RESOURCE_GROUP="RG1"
    MONITORING_STATUS="ACTIVE"
    RAW_MONITORING_STATUS="ONLINE_MONITORED"
    STARTUP_MODE=""
    

Local fix

Problem summary

  • Due to AIX 7.3 ksh93, clmgr query app is giving improper output
    

Problem conclusion

  • Fixed code in PowerHA to be inline with latest AIX 7.3 ksh93
    behavior.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ39953

  • Reported component name

    POWERHA SYSMIR

  • Reported component ID

    5765H3900

  • Reported release

    726

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-05-16

  • Closed date

    2022-05-16

  • Last modified date

    2022-05-16

  • APAR is sysrouted FROM one or more of the following:

    IJ37642

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    POWERHA SYSMIR

  • Fixed component ID

    5765H3900

Applicable component levels

[{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"726"}]

Document Information

Modified date:
19 December 2022