IJ38163: MAXIMO 7.6.1.2 - PSDI.APP.REPORT.VIRTUAL.QUICKPRINTSET.INIT() - DB CONNECTION LEAK

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Problem:
    The logs show that this is leaked for long periods of time.
    In one case it leaked for 6 minutes.
    
    Result
    The DB connection watchdog is generating a warning. MBOSet/DB
    connection related resources are being used too long.
    
    Stack trace:
    Create stack trace:
    psdi.server.DBManager.getConnection(DBManager.java:1472)
    psdi.mbo.MboSet.fetchMbos(MboSet.java:2905)
    psdi.mbo.MboSet.getMbo(MboSet.java:2121) psdi.app.report.virtua
    l.QuickPrintSet.init(QuickPrintSet.java:90)psdi.mbo.MboSet.init(
    psdi.mbo.MboSet.resetThis(MboSet.java:5258)
    psdi.mbo.MboSet.reset(MboSet.java:5174) psdi.webclient.controls
    .DynamicToolbar.buildButtonList(DynamicToolbar.java:97)psdi.webc
    r.java:66)psdi.webclient.system.session.WebClientSession.process
    ent(WebClientSession.java:6219)psdi.webclient.system.session.Web
    ueueRequest(WebClientSession.java:6441)psdi.webclient.system.ses
    bClientSession.java:897)psdi.webclient.system.session.AsyncReque
    (AsyncRequestManager.java:555)psdi.webclient.system.filter.HttpX
    ttpXFrameOptionsFilter.java:38)psdi.webclient.system.filter.MTCo
    Filter.java:53)com.ibm.ws.util.ThreadPool$Worker.run(ThreadPool.
    
    
    EXPECTED RESULTS:
    
    The connection gets closed after the report has run.
    
    REPORTED IN VERSION:
    
    Maximo: Tivoli's process automation engine
    7.6.1.2-IFIX20210323-1206 Build 20200715-0100 DB Build V7612-284
    HFDB Build HF7612-20
    IBM Maximo Asset Management Work Centers 7.6.0.4 Build
    20200715-0100 DB Build V7604-119 HFDB Build HF7680-10
    IBM Tpae Integration Framework
    7.6.1.2-MIF_7612_IFIX.20210303-1359 Build 20200715-1444 DB Build
    V7612-11
    IBM Maximo Asset Management 7.6.1.2 Build 20200715-0100 DB Build
    V7611-01
    IBM Maximo for Oil and Gas 7.6.1.0-20210111-0931 Build
    20161020-0803 DB Build V7610-139 HFDB Build HF7610-56
    IoT Connection Utility 7.6.0.3 Build 20200701-1409 DB Build
    V7603-32
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * MAXIMO                                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * DBConnection watchdog logs "BMXAA7084I - The database        *
    * connection has been opened for:..." for                      *
    * psdi.app.report.virtual.QuickPrintSet.init                   *
    ****************************************************************
    

Problem conclusion

  • _The fix for this APAR is contained in the following maintenance
    package: release\fix pack for Release 7.6.1.3 Product_
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ38163

  • Reported component name

    MAXIMO REPORTIN

  • Reported component ID

    TIVOREPTS

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-03-02

  • Closed date

    2022-05-18

  • Last modified date

    2024-10-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MAXIMO REPORTIN

  • Fixed component ID

    TIVOREPTS

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
30 October 2024