APAR status
Closed as program error.
Error description
A timing problem can cause the system to crash if an unconfiguration routine for a kernel extension unloads the extension before an associated kproc has had a chance to exit. This might occur if the kproc has a lower priority than the unconfiguration routine.
Local fix
Problem summary
A timing problem can cause the system to crash if an unconfiguration routine for a kernel extension unloads the extension before an associated kproc has had a chance to exit. This might occur if the kproc has a lower priority than the unconfiguration routine.
Problem conclusion
Add a dependency between a kproc and the kernel extension that defines it. This will prevent the kernel extension from being removed from memory until the kproc exists.
Temporary fix
Comments
7200-05 - use AIX APAR IJ20430
APAR Information
APAR number
IJ35899
Reported component name
AIX V7.2
Reported component ID
5765CD200
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2021-11-02
Closed date
2021-11-02
Last modified date
2021-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.2
Fixed component ID
5765CD200
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSVEF8"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"720","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information
Modified date:
03 November 2021