IBM Support

IJ35324: CLEARACA CMD FAILURE, DUE TO LINK DOWN, COULD CAUSE HANG.

 

APAR status

  • Closed as program error.

Error description

  • if clearaca cmd is rejected by the protocol driver due to
    link down the cmd will be failed back but the dev_info
    queue may be left in an error state cause cmd's to be in
    the
    pending queue.
    

Local fix

  • unmapping vfc adapter, wait 60 seconds, and re-map
    temporarily
    resolve the problem. Other cases may require a reboot.
    

Problem summary

  • i/o might hung with the following errpt entries,
    fscsi3  T FCP_ERR6 000000F0: Protocol driver rejected clear ACA
    

Problem conclusion

  • code modified to handle the link down properly
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ35324

  • Reported component name

    AIX V7.2

  • Reported component ID

    5765CD200

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-10-05

  • Closed date

    2021-10-05

  • Last modified date

    2022-11-14

  • APAR is sysrouted FROM one or more of the following:

    IJ33842

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.2

  • Fixed component ID

    5765CD200

Applicable component levels

  • R720 PSY U887389

       UP22/11/14 I 1000

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11S"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]