IBM Support

IJ32635: FC ADAPTER INPUT/OUTPUT STATISTICS MISREPORTED IN VIOS 3.1.X

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Description:
    FC Adapter output statistics (outreqs/outbytes) as
    reported
    by "fcstat -client"/"topas"/"nmon" can show a "0" or
    "near-zero" value and the actual counters can be
    aggregated into input statistics (inreqs/inbytes).
    
    The incorrect output will be seen on a physical fibre
    adapter on a VIO server, where the physical adapter
    serves
    as a backing device for virtual/NPIV adapters on client
    LPARs.
    
    Affected:
    Any supported VIOS
    

Local fix

  • Not Available
    

Problem summary

  • Tools like fcstat nmon shows wrong statistics for the physical
    adapter when running IO from NPIV client.  It shows outreqs,
    outbytes stats count added to inreqs, inbytes.
    

Problem conclusion

  • Code fixed to correct wrong flags set in IO buffer.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ32635

  • Reported component name

    VIRTUAL I/O SER

  • Reported component ID

    5765G3400

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2021-05-12

  • Closed date

    2021-06-09

  • Last modified date

    2021-06-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    VIRTUAL I/O SER

  • Fixed component ID

    5765G3400

Applicable component levels

  • R310 PSY

       UP

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SUNSET","label":"PRODUCT REMOVED"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"310","Line of Business":{"code":"LOB57","label":"Power"}}]

Document Information

Modified date: