Error description

  • DESCRIPTION:
    
    A POLINE is having an Item as Charge to Asset.
    After completing the receiving for such a PO, Wrong Rotating
    Asset parent number is assigned to the actual Asset.
    
    
    
    STEPS
    TO REPRODUCE:
    
    1) Create an Item
    
    (i) Go to Inventory; Item
    Master Application
    
    (ii) Create a new Item; TESTITEM10;
    Rotating: YES; "Attach to Parent Asset on Issue?": YES
    
    (iii)
    From More Actions; Add Items to Storeroom: CENTRAL; Item:
    TESTITEM10; Unit Cost: 1; Default Bin: BIN1; Issue Unit: EACH;
    Order Unit: EACH
    
    (iv) Change Status to ACTIVE; after selecting
    "Roll New Status to Organizations and Inventory?": YES
    
    
    
    2)
    Create a Purchase Order
    
    (i) Go to Purchasing; Purchase Orders
    Application
    
    (ii) Create a new PO: TESTPO10; Vendor Company:
    SKF;
    
    (iii) Switch to POLINES tab; Under POLines; Click New
    Row; Add Line Item: TESTITEM10; Conversion Factor: 1; Charge to
    Asset: CAL300; Ensure "Issue on Receipt?" is now checked.
    
    (iv)
    Save; Approve the Purchase Order
    
    
    
    3) Complete the
    Receiving
    
    (i) Go to Purchasing; Receiving Application
    
    (ii)
    List the PO record: TESTPO10; Under Material Receipts; Select
    Ordered Items; Select the POLine having item: TESTITEM10; Click
    Ok; Save;
    
    (iii) Observe: The Insp. Status of the POLINE1;
    Item: TESTITEM10 is WASSET with Type: RECEIPT; Charge to Asset:
    CAL300
    
    (iv) Go to More Actions-> Receive Rotating Item;
    Description: TESTITEM10; Item: TESTITEM10. Enter Asset as
    TESTASSET10; Click OK.
    
    (iii) Expand the POLine1 to view the
    results. Observe: There are two entries, one for Type: RECEIPT
    and another for Type: TRANSFER.
    
    (iv) Charge to Asset Under
    Type: RECEIPT is shows as CAL300. But Under Type: TRANSFER,
    Charge to Asset: <IS_BLANK>
    
    
    
    4) Go to Assets; Assets
    Application
    
    (i) Find the Asset: TESTASSET10;
    
    (ii) Observe
    both ASSET.ASSETNUM and ASSET.PARENT is shown as TESTASSET10.
    
    
    
    
    RESULT: Both AssetNum and Parent AssetNum are having the same
    Id(number, here -TESTASSET10) which is wrong and creates a loop
    in the hierarchy.
    
    
    
    EXPECTED RESULT:
    
    In the Assets
    Application:
    
    (i) both AssetNum and Parent AssetNum should not
    be having the same Id.
    
    (ii) Parent AssetNum should inherit
    Charge to Asset value, In this case - 'CAL300'.
    
    
    
    REPORTED IN
    VERSION:
    
    Tivoli's process automation engine 7.6.1.2
    
    ==========
    =====================================================
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Maximo users                                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The wrong Rotating Asset parent number is assigned to the    *
    * Asset after receiving a PO with a POLine that has an Item as *
    * Charge to Asset and the Item has "Attach to Parent Asset on  *
    * Issue?" checked.                                             *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    package: release\fix pack for Release 7.6.1.3 Product
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ31793

  • Reported component name

    MAXIMO ASST MGM

  • Reported component ID

    5724R46AM

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-03-25

  • Closed date

    2021-05-19

  • Last modified date

    2021-05-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MAXIMO ASST MGM

  • Fixed component ID

    5724R46AM

Applicable component levels

[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761"}]