APAR status
Closed as program error.
Error description
Few RAS enhancements are implemented in PowerHA 725 release
Local fix
NA
Problem summary
This APAR address the following. 1. More logs are coming from cl_cbm_list, cl_cbm_list_storage_profile and cl_cbm_get_bp_attribues in hacmp.out. 2. clmgr modify rg is giving error 2 times when the provided resource group does not exists. 3. clmgr modify bp is not throwing any message if we are not providing any attributes for modify bp. In addtion to this, other python related issues have been fixed.
Problem conclusion
1. Removed unnecessary logging from clmgr q bp, clmgr q sts BACKUP=1 in hacmp.out. 2. Added proper checks in clmgr modify rg and clmgr modify bp. Fixed python related issues.
Temporary fix
Comments
APAR Information
APAR number
IJ31527
Reported component name
POWERHA SYSMIR
Reported component ID
5765H3900
Reported release
725
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2021-03-17
Closed date
2021-04-22
Last modified date
2021-04-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
POWERHA SYSMIR
Fixed component ID
5765H3900
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"725","Line of Business":{"code":"LOB57","label":"Power"}}]