APAR status
Closed as program error.
Error description
Due to the current approach used by the TEP client to construct a valid URL based on relative document paths, if a networked device in the environment is known to the DNS (or the TEP client machine's local hosts file) using a domain name that begins with "classes", the URL construction will fail to produce the correct fully-qualified URI.
Local fix
1) If the network device associated with a domain name that begins with classes is no longer in operation, the device should be varied offline and the corresponding DNS entry should be removed. 2) The network device associated with a domain name that begins with classes can be renamed so that the leading domain qualifier is assigned a value other than classes.
Problem summary
TEP Browser View generates failing URL's when document paths begin with "classes" qualifier. Due to the approach used by the TEP client to construct a valid URL based on relative document paths, if a networked device in the environment is known to the DNS (or the TEP client machine's local hosts file) using a domain name that begins with "classes" qualifier, the URL construction algorithm associated with the TEP Browser View will fail to produce the correct fully-qualified URI. This typically results in an HTTP error, and the expected document is not rendered.
Problem conclusion
The TEP Browser View implementation has been changed to check for the existence of a leading "classes" qualifier in the relative document path, and then properly handle the case where a networked device with that name is known to the DNS. The fix for this APAR is contained in the following maintenance packages: | service pack | 6.3.0.7-TIV-ITM-SP0008
Temporary fix
Comments
APAR Information
APAR number
IJ30941
Reported component name
TEPS
Reported component ID
5724C04PS
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-02-18
Closed date
2021-08-11
Last modified date
2021-08-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEPS
Fixed component ID
5724C04PS
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
08 March 2023