IBM Support

IJ30581: CONFIGURE GANTT VIEW PROPERTIES IS PERSISTENT FIELD FOR STARTTIMEPROPERTY IS NOT SET TO READ ONLY.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Changing the StartTime Gantt view property to non-persistent
    leads to data display issues with the Start time when looking at
    graphical assignment and scheduler records. The field should be
    set to read only to prevent any changes being made to it.
    
    
    STEPS TO REPRODUCE:
    
    1. Open Configure Gantt View Properties: Default Settings
    Search for startTime and expand the field, we should see that is
    Persistent is checked.
    
    2. Remove the checkmark from the field, apply and save the
    changes.
    
    3. Open an existing graphical assignment or scheduler record,
    refresh the record and look at the start date. It will no longer
    display as a date format, instead it shows as just random
    numbers.
    
    The Is Persistent will be made read only to stop this from
    happening.
    
    RESULTS:
    
    Start date format is no longer a date format.
    
    Reported in Version:
    
    Maximo Asset Management Scheduler 7.6.8.0
    

Local fix

  • 1. Open Configure Gantt View Properties: Default Settings
    2. Search for startTime and expand the field, we should see that
    is Persistent is not checked.
    3.Place a checkmark in the field, apply and then OK.
    4. Refresh schedule and all should be working as needed.
    

Problem summary

Problem conclusion

  • Fix has been made to fix....The fix for this APAR is contained
    in the following maintenance package:
    		 | release\fix pack\interim fix for  Release 7.6.1.3 of Base
    Services(Scheduler 768x)
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ30581

  • Reported component name

    MAXIMO SCHEDULE

  • Reported component ID

    5724R46SE

  • Reported release

    768

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-02-03

  • Closed date

    2021-02-10

  • Last modified date

    2024-10-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MAXIMO SCHEDULE

  • Fixed component ID

    5724R46SE

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9NUN","label":"Maximo Asset Management Scheduler"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"768","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
30 October 2024