APAR status
Closed as fixed if next.
Error description
The SNMP Gateway does not honour the setting for Gate.SNMP.Timeout as expected when the SNMP listener is unavailable. It is expected that the settings Gate.SNMP.Timeout Gate.SNMP.Retries allow for a period of time for which to attempt to resend traps that were not sent Presently a non-listening port returns immediately Technical description: The NetSNMP snmp_send function operates asynchronously, so the API returns before the transport layer operation finishes, which prevents the failure at the TCP level being reflected in the gateways retry function.
Local fix
Ensure the SNMP listener is always available using HA facilities
Problem summary
**************************************************************** * PROBLEM DESCRIPTION: SNMP GATEWAY : PROBLEM WITH RETRYING TO * * SEND TRAPS WHEN THE SNMP LISTENER IS DOWN * * * **************************************************************** * RECOMMENDATION: GATEWAY-NCO-G-XML-11.1.0 * * * ****************************************************************
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
IJ28244
Reported component name
OMNI SNMP FORW
Reported component ID
5724O71SP
Reported release
100
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-09-22
Closed date
2022-05-20
Last modified date
2022-05-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSSHTQ","label":"Tivoli Netcool\/OMNIbus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"100"}]
Document Information
Modified date:
21 May 2022