IBM Support

IJ27786: LPAR CRASHES IN VFC STACK ON P9 APPLIES TO AIX 7200-05

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • AIX lpar may end up with a crash with stack showing
    vfc_process_mad. Particularly observed on P9 and above.
    The AIX vfc client driver did not synchronize the command
    buffer before sending the cmd address to VIOS vfc-host.
    Consequently VIOS vfc-host would process a stale cmd and
    when the response for stale cmd is processed on AIX lpar, it
    might crash the operating system.
    

Local fix

Problem summary

  • AIX lpar may end up with a crash with stack showing
    vfc_process_mad. Particularly observed on P9 and above.
    The AIX vfc client driver did not synchronize the command
    buffer before sending the cmd address to VIOS vfc-host.
    Consequently VIOS vfc-host would process a stale cmd and
    when the response for stale cmd is processed on AIX lpar, it
    might crash the operating system.
    

Problem conclusion

  • Code fix to synchronize the command buffer before
    sending the cmd to VIO.
    

Temporary fix

Comments

  • 7100-05 - use AIX APAR IJ28592
    7200-05 - use AIX APAR IJ27786
    

APAR Information

  • APAR number

    IJ27786

  • Reported component name

    AIX V7.2

  • Reported component ID

    5765CD200

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2020-09-08

  • Closed date

    2020-09-08

  • Last modified date

    2021-02-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IJ28565 IJ28592 IJ28596

Fix information

  • Fixed component name

    AIX V7.2

  • Fixed component ID

    5765CD200

Applicable component levels

  • R720 PSY U879796

       UP20/11/04 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSVEF8","label":"AIX 7.2 Enterprise Edition"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"720","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]