APAR status
Closed as program error.
Error description
PRS was updated with APAR IJ18166 to support RHEL8. However, the output shows only the supported operating system and there is no further information such as CpuArchitecture, Memory, Disk, os.space, or os.package. This seems due to the updated release name in "/etc/redhat-release".
Local fix
Modify the line 62 of the "NOC_08010000.cfg" which comes with IJ18166 update. Before: [OSType:RedHatEnterpriseLinuxServer7.* |RedHatEnterpriseLinuxServer8.*][CPUArch:x86_64][OSArch:64-bit] After: [OSType:RedHatEnterpriseLinuxServer7.*|RedHatEnterprise Linux8.*][CPUArch:x86_64][OSArch:64-bit]
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of IBM Prerequisite Scanner wishing to check * * prerequisites prior to installing Netcool/OMNIbus on RHEL * * 8.x systems * **************************************************************** * PROBLEM DESCRIPTION: * * The Prerequisite Scanner would not perform all necessary * * checks when run on RHEL 8.x systems. * **************************************************************** * RECOMMENDATION: * * Apply the maintenance vehicles listed in the Problem * * Conclusion. * ****************************************************************
Problem conclusion
The fix for this APAR is contained in the following maintenance packages: | interim fix | http://ibm.biz/BdzukA
Temporary fix
Comments
APAR Information
APAR number
IJ27677
Reported component name
NETCOOL/OMNIBUS
Reported component ID
5724O4800
Reported release
810
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-09-02
Closed date
2021-02-24
Last modified date
2021-02-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
NETCOOL/OMNIBUS
Fixed component ID
5724O4800
Applicable component levels
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSHTQ","label":"Tivoli Netcool\/OMNIbus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"810"}]
Document Information
Modified date:
26 February 2021