Error description

  • A PowerHA 7.2.3.2 system, which includes APAR IJ04853,
    rejects a valid request to triple mirror a volume group
    whose current layout is:
    
    vgdata:
    LV NAME   TYPE   LPs    PPs    PVs  LV STATE   MOUNT
    POINT
    sapdata1  jfs2   3038   6076   4    open/syncd /sapdata1
    
    The error message is --
    cl_mirrorvg: No logical volumes in the volume group
    vgdata
       to mirror
    

Local fix

  • Find the node on which the volume group is on line, and
    use the base AIX mirrorvg command.
    

Problem summary

  • When trying to perform triple mirroring a volume group the
    request was rejected with the following error:
    cl_mirrorvg: No logical volumes in the volume group vgdata to
    mirror
    

Problem conclusion

  • Made code change in logic i.e instead of using hardcoded values,
    checking the condition in cl_mirrorvg file based on the number
    of copies provided
    

Temporary fix

  • Not available
    

Comments

APAR Information

  • APAR number

    IJ26743

  • Reported component name

    POWERHA SYSMIR

  • Reported component ID

    5765H3900

  • Reported release

    722

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2020-07-31

  • Closed date

    2020-07-31

  • Last modified date

    2020-07-31

  • APAR is sysrouted FROM one or more of the following:

    IJ25482

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    POWERHA SYSMIR

  • Fixed component ID

    5765H3900

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"722","Line of Business":{"code":"LOB57","label":"Power"}}]

Document Information

Modified date:
01 August 2020