Error description

  • On systems that are booted in FIPS, the ssh
    client produces extra messages
    on stdout.  The message "FIPS mode
    initialized" causes GPFS command
    to fail.  GPFS requires that the shell
    command produces no extraneous
    messags.
    

Local fix

  • Disable FIPS at boot or write a wrapper
    script that will remove the
    extraneous message from ssh.
    The wrapper script can be added to
    the GPFS remote shell command.
    

Problem summary

  • On systems that are booted in FIPS, the ssh
    client produces extra messages
    on stdout.  The message "FIPS mode
    initialized" causes GPFS command
    to fail.  GPFS requires that the shell
    command produces no extraneous
    messags.
    

Problem conclusion

  • Work Around: 
    Disable FIPS at boot or write a wrapper
    script that will remove the
    extraneous message from ssh.
    The wrapper script can be added to
    the GPFS remote shell command.
    Problem trigger:
    Command failure on systems that
    booted in FIPS mode.
    Symptom:
        Error output/message
    Platforms affected:
        ALL Linux OS environments
    Functional Area affected:
        Admin Commands
    Customer Impact:
    High Importance: an issue which will cause a degradation
    of the system in some manner, or loss
    of a less central capability
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ25685

  • Reported component name

    SPEC SCALE STD

  • Reported component ID

    5737F33AP

  • Reported release

    505

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-06-19

  • Closed date

    2020-06-19

  • Last modified date

    2020-06-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPEC SCALE STD

  • Fixed component ID

    5737F33AP

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
20 June 2020