APAR status
Closed as program error.
Error description
When a conflict arises on clearance, the application does not allow the change of status from RESTORE to RELEASE even though there has been an acceptance related to the conflict. Steps to replicate: 1- Create CL 1000, add Tag 1000 on VALVE001, position OPEN. 2- Move CL 1000 to APPR. 3- Create CL 1001, add Tag 1001 on VALVE001, position CLOSED. 4- Move CL 1001 to READY, Accept conflict. 5- Set Restoration position on Tag 1001 to CLOSED, set Restoration sequence. 6- Move CL 1001 to RESTORE, Accept Conflict. 7- Try to change CL 1001 status back to RELEASE RESULT: you get an error message: BMXAK0112E - This status change is not allowed. EXPECTED RESULT You should allow the change status and display the dialog box for accepting the conflict because Tag 1000 is still at DRAFT. . System info: IBM Maximo for Nuclear Power 7.6.1.0 Tivoli's process automation engine 7.6.0.8 . Application Clearances . Industry Solution Nuclear
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All user of Maximo for Nuclear Power * **************************************************************** * PROBLEM DESCRIPTION: * * USER IS UNABLE TO CHANGE CLEARANCE STATUS FROM RESTORE TO * * RELEASE WHEN A CONFLICT EXISTS BUT HAS BEEN ACCEPTED * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Changed the status change process so that it can allow status change from restore to release when all possible existing conflicts have been accepted.
Temporary fix
Comments
APAR Information
APAR number
IJ17525
Reported component name
MAXIMO FOR NUCL
Reported component ID
5724R5300
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-07-11
Closed date
2019-08-05
Last modified date
2024-10-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MAXIMO FOR NUCL
Fixed component ID
5724R5300
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSLL8M","label":"Maximo for Nuclear Power"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
30 October 2024