IBM Support

IJ12143: TCP SESSION HANG/TIMEOUT OR POSSIBLE UNDETECTED DATA CORRUPTION APPLIES TO AIX 6100-09

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • *
    * USERS AFFECTED:
      * Systems running the AIX 6100-09 Technology Level
      * or VIOS 2.2.5.50 or VIOS 2.2.6.3x
      * with devices.common.IBM.ethernet.rte at
      * the 6.1.9.400 level.
    *
      * PROBLEM DESCRIPTION:
      * TCP sessions through VIOS SEA can slow, hang, timeout, or
      * cause extra zeroes to be added to the tcp payload data.
      *
      * This can happen if the SEA on the VIOS is configured with:
      * - large_receive=yes (non-default setting)
      * AND
      * - plso_bridge=yes (default setting on affected VIOS levels)
      *
      * This includes data transferred between VIOSes during LPM.
      *
    * The APAR/iFix should be applied to the VIOS to prevent these
      * issues.
      * As a workaround, the SEA attributes can be modified:
      * For SEAs bridging traffic to AIX LPARs only, set
      * plso_bridge=no
      * For SEAs bridging traffic to any Linux LPARs, set
      * large_receive=no
    *
      * RECOMMENDATION:
      * Install APAR IJ12143.
      * Prior to fix availability, an interim fix is available from
      * either
      * ftp://aix.software.ibm.com/aix/ifixes/ij12143/
      * https://aix.software.ibm.com/aix/ifixes/ij12143/
      * Installation of the ifix requires a reboot.
    *
    

Local fix

  • disable "plso_bridge" on all SEA devices:
    (use the right SEA adapter number instead of "X")
    $ chdev -dev entX -attr plso_bridge=no
    The change is dynamic and doesn't require a reboot.
    

Problem summary

  • *
      * USERS AFFECTED:
      * Systems running the AIX 6100-09 Technology Level
      * or VIOS 2.2.5.50 or VIOS 2.2.6.3x
      * with devices.common.IBM.ethernet.rte at
      * the 6.1.9.400 level.
    *
      * PROBLEM DESCRIPTION:
      * TCP sessions through VIOS SEA can slow, hang, timeout, or
      * cause extra zeroes to be added to the tcp payload data.
      *
      * This can happen if the SEA on the VIOS is configured with:
      * - large_receive=yes (non-default setting)
      * AND
      * - plso_bridge=yes (default setting on affected VIOS levels)
      *
      * This includes data transferred between VIOSes during LPM.
      *
    * The APAR/iFix should be applied to the VIOS to prevent these
      * issues.
      * As a workaround, the SEA attributes can be modified:
      * For SEAs bridging traffic to AIX LPARs only, set
      * plso_bridge=no
      * For SEAs bridging traffic to any Linux LPARs, set
      * large_receive=no
    *
      * RECOMMENDATION:
      * Install APAR IJ12143.
      * Prior to fix availability, an interim fix is available from
      * either
      * ftp://aix.software.ibm.com/aix/ifixes/ij12143/
      * https://aix.software.ibm.com/aix/ifixes/ij12143/
      * Installation of the ifix requires a reboot.
    *
    

Problem conclusion

  • Code fixed to avoid the corruption.
    

Temporary fix

  •   *********
      * HIPER *
      *********
    

Comments

  • 6100-09 - use AIX APAR IJ12143
    7100-04 - use AIX APAR IJ12816
    7100-05 - use AIX APAR IJ12817
    7200-01 - use AIX APAR IJ12818
    7200-02 - use AIX APAR IJ12819
    7200-03 - use AIX APAR IJ12809
    

APAR Information

  • APAR number

    IJ12143

  • Reported component name

    VIRTUAL I/O SER

  • Reported component ID

    5765G3400

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-12-13

  • Closed date

    2019-01-17

  • Last modified date

    2019-11-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IJ12809 IJ12816 IJ12817 IJ12818 IJ12819 IJ12820

Fix information

  • Fixed component name

    VIRTUAL I/O SER

  • Fixed component ID

    5765G3400

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSAVPM","label":"PowerVM VIOS Standard Edition"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]

Document Information

Modified date: