Error description

  • Adapter firmware upgrade could fail with FCA_ERR6
    and sense data 518
    
    -------------Cut-------------------------
    LABEL:      FCA_ERR6
    ..
    ..
    ..
    
    Detail Data
    SENSE DATA
    0000 0020 0000 0518 0000 0005 0000 0000 0000 00AC 0000
    0000 1000 0090 FAA0 5444
                    ^^^
    -------------Cut-------------------------
    
    This could happen under the following sequence of events:
    
    1) Firmware upgrade is performed on an unused fcs
    instance
    2) a monitoring application like fcstat opens the same
    adapter
       at the same time
    

Local fix

  • 1) retry adapter microcode upgrade
    or
    2) perform microcode upgrade on actively used fcs
    instances
    or
    3) stop monitoring applications from polling the adapter
    or
    4) If all adapters fcs instances are unused, place
    protocol driver associated with
       the firmware upgrade in a defined state with the
    following command:
    
    Example: Assuming your upgrading firmware on fcs0
    rmdev -Rl fscsi0
    
    The above will place fscsi0 in a defined state
    

Problem summary

  • Adapter microcode update might fail with FCA_ERR6 and sense
    code 518
    

Problem conclusion

  • code modified to return error to the open thread, if adapter
    microcode update is already in progress
    

Temporary fix

Comments

  • ×**** PE20/05/15 PTF IN ERROR. SEE APAR IJ22290  FOR DESCRIPTION
    ×**** PE22/09/08 PTF IN ERROR. SEE APAR IJ38520  FOR DESCRIPTION
    

APAR Information

  • APAR number

    IJ08633

  • Reported component name

    AIX V7.2

  • Reported component ID

    5765CD200

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-08-20

  • Closed date

    2018-08-20

  • Last modified date

    2022-09-08

  • APAR is sysrouted FROM one or more of the following:

    IJ06644

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.2

  • Fixed component ID

    5765CD200

Applicable component levels

  • R720 PSY U880566

       UP19/10/31 I 1000

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11S"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date:
08 September 2022