A fix is available
APAR status
Closed as program error.
Error description
Adapters using shientdd can log the following errors when link goes down and later up: SHIENT_PLINK_UP SHIENT_SW_ERR LDMP_COMPLETE After the livedump on all adapter ports the ports might be in an unusable state requiring reboot or rmdev/mkdev.
Local fix
Disable the livedump feature: #‌‌ dumpctrl ldmpoff -P #‌‌ bosboot -a #‌‌ shutdown -Fr
Problem summary
shientdd driver takes adapter livedumps and logs permanent error SHIENT_SW_ERR in the errpt.
Problem conclusion
Modified the code which was wrongly triggering the livedump.
Temporary fix
Comments
APAR Information
APAR number
IJ08481
Reported component name
AIX V7.2
Reported component ID
5765CD200
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2018-08-15
Closed date
2018-08-15
Last modified date
2019-11-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.2
Fixed component ID
5765CD200
Applicable component levels
R720 PSY U875523
UP18/09/13 I 1000
PTF to Fileset Mapping
U875523 devices.ethernet.shi.rte 7.2.3.0
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSVEF8","label":"AIX 7.2 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11S","label":"AIX 7.2 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"","label":""}}]