IBM Support

IJ06644: ADAPTER FIRMWARE UPGRADE CAN FAIL OR ADAPTER MAY BECOME UNUSABLEAPPLIES TO AIX 6100-09

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • **************************************************************
    * USERS AFFECTED:
    * Systems running the AIX 6100-09 Technology Level
    * or VIOS 2.2.x.x
    * with devices.pciex.df1060e214103404.com below the
    * 6.1.9.401 level.
      **************************************************************
    * ERROR DESCRIPTION:
    * Fibre-Channel adapters utilizing the emfcdd driver could be
    * impacted if an adapter firmware upgrade is performed on
    * unused fcs instances while, at the same time, running fcstat
    * on another unused fcs instance associated with the same
    * adapter.
    *
    * Other performance or health related processes may also
    * trigger this if they also open unused fcs instances
    * similarly to fcstat.
    *
    * The firmware update could fail or in some cases the adapter
    * firmware may become faulty where the physical adapter is no
    * longer usable.
    *
    * This problem has not been observed if all fcs instances
    * associated with the physical adapter are in-use during the
    * adapter firmware upgrade.
    *
    * Find out if a system has any adapters using an affected
    * driver with lsdev, for example:
    *
    * # lsdev -F "name ddins" | grep emfcdd
    *
    * Note: on a VIOS, this must be run as root using
    * 'oem_setup_env'.
      **************************************************************
    * RECOMMENDATION:
    * Install APAR IJ06644.
    * Prior to fix availability, an interim fix is available from
    * either
    * ftp://aix.software.ibm.com/aix/ifixes/ij06644/
    * https://aix.software.ibm.com/aix/ifixes/ij06644/
    * Installation of the ifix requires a reboot.
      **************************************************************
    

Local fix

  • 1) retry adapter microcode upgrade
    or
    2) perform microcode upgrade on actively used fcs
    instances
    or
    3) stop monitoring applications from polling the adapter
    or
    4) If all adapters fcs instances are unused, place
    protocol driver associated with
       the firmware upgrade in a defined state with the
    following command:
    
    Example: Assuming your upgrading firmware on fcs0
    rmdev -Rl fscsi0
    
    The above will place fscsi0 in a defined state
    

Problem summary

  • Adapter microcode update might fail with FCA_ERR6 and sense
    code 518
    

Problem conclusion

  • code modified to return error to the open thread, if adapter
    microcode update is already in progress
    

Temporary fix

  •   *********
      * HIPER *
      *********
    

Comments

APAR Information

  • APAR number

    IJ06644

  • Reported component name

    VIRTUAL I/O SER

  • Reported component ID

    5765G3400

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-05-24

  • Closed date

    2018-08-02

  • Last modified date

    2019-11-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IJ08633 IJ08641 IJ09173 IJ09174 IJ09175 IJ09176 IJ09583

Fix information

  • Fixed component name

    VIRTUAL I/O SER

  • Fixed component ID

    5765G3400

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSAVPM","label":"PowerVM VIOS Standard Edition"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]

Document Information

Modified date:
06 August 2024