IBM Support

IJ06133: SUMA MAY CAUSE A NULLPOINTEREXCEPTION APPLIES TO AIX 7100-05

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Running suma with "Action=Metadata" may generate the
    following error message.
    
    suma -x -a Action=Metadata -a RqType=SP -a
    RqName=7200-02-02 -a DLTarget=/tmp
    Exception in thread "main" java.lang.NullPointerException
            at ECCWrapper.orderUpdates(ECCWrapper.java:551)
            at ECCWrapper.main(ECCWrapper.java:153)
    0500-012 An error occurred attempting to download.
    

Local fix

  • Include the build date in RqName in order to get the
    metadata.
    
    suma -x -a Action=Metadata -a RqType=SP -a
    RqName=7200-02-02-1810 -a DLTarget=/tmp
    

Problem summary

  • Running suma with "Action=Metadata" may generate the
    following error message.
    
    suma -x -a Action=Metadata -a RqType=SP -a
    RqName=7200-02-02 -a DLTarget=/tmp
    Exception in thread "main" java.lang.NullPointerException
            at ECCWrapper.orderUpdates(ECCWrapper.java:551)
            at ECCWrapper.main(ECCWrapper.java:153)
    0500-012 An error occurred attempting to download.
    

Problem conclusion

  • Modified the way we handle exceptions.
    

Temporary fix

Comments

  • 6100-09 - use AIX APAR IJ06160
    7100-05 - use AIX APAR IJ06133
    7200-03 - use AIX APAR IJ06197
    

APAR Information

  • APAR number

    IJ06133

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-05-02

  • Closed date

    2018-05-02

  • Last modified date

    2018-09-21

  • APAR is sysrouted FROM one or more of the following:

    IJ05715

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U879312

       UP18/09/06 I 1000

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11R"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date:
19 April 2022