APAR status
Closed as program error.
Error description
************************************************************** * USERS AFFECTED: * Systems running the AIX 7100-04 Technology Level * with bos.cluster.rte at or below the 7.1.4.33 * level. ************************************************************** * ERROR DESCRIPTION: * PowerHA Verify & Sync, clcmd, or other processes that * utilize clcomd may hang. * Large numbers of zombie processes for clcmd, clmgr, or * similar commands may be seen if this is occurring. * * Restarting clcomd with stopsrc/startsrc will clean up zombie * processes and allow clcomd to process new events again; * however the issue could re-occur again later, until the fix * is applied. ************************************************************** * RECOMMENDATION: * Install APAR IJ04512. * Prior to fix availability, an interim fix is available from * either * ftp://aix.software.ibm.com/aix/ifixes/ij04512/ * https://aix.software.ibm.com/aix/ifixes/ij04512/ * Installation of the ifix does not require a reboot. **************************************************************
Local fix
Stopping and restarting clcomd (stopsrc -s clcomd; startsrc -s clcomd) will allow clcomd to process new events, and clean up existing zombie processes. However, it will not prevent further hangs.
Problem summary
Operations involving clcomd, such as PowerHA Verify & Sync and clcmd commands may hang.
Problem conclusion
Remove unnecessary connection conflict logic that led to an infinite loop of clcomd refreshes.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
IJ04512
Reported component name
AIX V7.1
Reported component ID
5765H4000
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-02-28
Closed date
2018-02-28
Last modified date
2019-01-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.1
Fixed component ID
5765H4000
Applicable component levels
R710 PSY U879028
UP19/01/23 I 1000