Error description
1. Within a smartmodel based definition I am unable to create an evaluation on XPATH='Configuration/Interface/GigabitEthernet/Authentication' as that path is not present. 2. Also, the NCM fails to identify 'dot1x' lines within an interface(XPATH=Configuration/Interface/GigabitEthernet/dot1x) even though it is present in Native Configuration of the device. I checked the worker.log and found that the the commands are likely unmodelled (for both Cisco 3560 and 3750) => 2018.01.24 05:34:46 GMT+00:00 OperationRunner-018-WorkerServer02 WARN WORKER WorkerServer02 com.intelliden.common.utility.logging.IntellidenLogger :: [com.intelliden.icos.util.cli2xml.0007] Commands found conflicting Schema Un-Modeled command: 'authentication critical recovery delay 3000' at reformmatted Line : 34 ... 2018.01.24 05:34:46 GMT+00:00 OperationRunner-018-WorkerServer02 WARN WORKER WorkerServer02 com.intelliden.common.utility.logging.IntellidenLogger :: [com.intelliden.icos.util.cli2xml.0007] Commands found conflicting Schema Rejecting command: 'dot1x pae authenticator'; this line was a child of: 'authentication timer restart 0' at reformmatted Line : 245 2018.01.24 05:34:46 GMT+00:00 OperationRunner-018-WorkerServer02 WARN WORKER WorkerServer02 com.intelliden.common.utility.logging.IntellidenLogger :: [com.intelliden.icos.util.cli2xml.0007] Commands found conflicting Schema Rejecting command: 'dot1x timeout tx-period 5'; this line was a child of: 'authentication timer restart 0' at reformmatted Line : 246 2018.01.24 05:34:46 GMT+00:00 OperationRunner-018-WorkerServer02 WARN WORKER WorkerServer02 com.intelliden.common.utility.logging.IntellidenLogger :: [com.intelliden.icos.util.cli2xml.0007] Commands found conflicting Schema Rejecting command: 'storm-control broadcast level 5.00'; this line was a child of: 'authentication timer restart 0' at reformmatted Line : 247
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: * * Users using CISCO 3560 AND * * 3750 drivers * **************************************************************** * PROBLEM DESCRIPTION: * * Modelling issue * **************************************************************** * RECOMMENDATION: * * New driver is provided to customer and it's also included in * * the latest driver's code baseline. * ****************************************************************
Problem conclusion
New driver is provided to customer and it's also included in the latest driver's code baseline.
Temporary fix
Comments
APAR Information
APAR number
IJ03802
Reported component name
N/C CONFIG MGR(
Reported component ID
5724Z3100
Reported release
642
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-02-01
Closed date
2018-02-16
Last modified date
2018-02-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
N/C CONFIG MGR(
Fixed component ID
5724Z3100
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS7UH9","label":"Tivoli Netcool Configuration Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"642","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
16 February 2018