APAR status
Closed as program error.
Error description
Even though the interface label and address are defined in the PowerHA and AIX ODMs, verification returns a false error. This error can occur at any time. ERROR: Interface <<iplabel>> (<<ipaddr>>) is not configured in AIX on node: <<nodename>> Please check to ensure the interface is properly defined to AIX. If the 'smitty chinet' and change network interface: <<en#>> to the above IP definition.
Local fix
A possible workaround is to remove the odmcache directory /var/hacmp/odmcache/* and retry verification.
Problem summary
Even though the interface label and address are defined in the PowerHA and AIX ODMs, verification returns a false error. This error can occur at any time. ERROR: Interface <> (<>) is not configured in AIX on node: <> Please check to ensure the interface is properly defined to AIX. If the 'smitty chinet' and change network interface: <> to the above IP definition.
Problem conclusion
Current logic of odmcache sometimes mistakenly takes local node name instead of the expected remote node name. Hence, /var/hacmp/odmcache directory would get corrupted for the remote node's odmcache data causing the clver checker to misleadingly complain about a non existent problem. Now, the logic has been modified to resolve this odmcache issue.
Temporary fix
Comments
APAR Information
APAR number
IJ02957
Reported component name
POWERHA SYSMIR
Reported component ID
5765H3900
Reported release
713
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2018-01-05
Closed date
2018-01-23
Last modified date
2018-01-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
POWERHA SYSMIR
Fixed component ID
5765H3900
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"","label":""}}]