Direct links to fixes
APAR status
Closed as program error.
Error description
Clients using clmgr to convert from Multicast -> Unicast may see an error if VERBOSE_LOGGING=high. . The clmgr command such as the following: . #clmgr modify cluster HEARTBEAT_TYPE=unicast . may generate an error as follows: . ERROR: one or more nodes in the cluster does not currently have unicast capability. Please perform the necessary updates on all nodes to allow a unicast-based cluster
Local fix
Do not use VERBOSE_LOGGING=high when using clmgr
Problem summary
While running clmgr command to convert from Multicast -> Unicast, parsing incorrect cluster node capability in case of VERBOSE_LOGGING set as 'high'.
Problem conclusion
Modified the code to parse the correct value of node capability.
Temporary fix
Comments
APAR Information
APAR number
IJ01168
Reported component name
POWERHA SYSMIR
Reported component ID
5765H3900
Reported release
721
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2017-11-01
Closed date
2017-11-01
Last modified date
2017-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
POWERHA SYSMIR
Fixed component ID
5765H3900
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
19 October 2021