  • OEM vendor products that have caused problems in DB2 or IRLM
    =================KF 04/21/05====================================
    ABEND0C4 RC00000004 DSNXERT 00B0 007A from DB2 V8
    Related to trigger wild branch from CA ITH$ENTY to DSNXERT
    Apply CA PTF UDTE149
    ================LCK ============================================
     Any batch job or TSO user that issues a DISplay command for
     databases or utilites is hung.
     SYSLOG shows timeouts with CORRELATION-ID=021.EUSDTU09
     DSNT376I -D2D6 PLAN=DSNUTIL WITH
         CORRELATION-ID=ZCAACL12
         CONNECTION-ID=UTILITY
         LUW-ID=B1001.CODB2T6.BCD8C8968C26=22715
         THREAD-INFO=CAA&:*:*:*
         IS TIMED OUT. ONE HOLDER OF THE RESOURCE IS PLAN= WITH
         CORRELATION-ID=021.EUSDTU09
         CONNECTION-ID=D2D6
         LUW-ID=B1001.CODB2T6.BCD8E81452F2
         THREAD-INFO=SYSOPR:*:*:*
         ON MEMBER D2D6
     dump shows task for  CORRELATION-ID=021.EUSDTU09 is
     processing in CASR230K CA code. This task was in the process
     of switching execution units to do the DISPLAY command.
    The fix is TE49574 from CA
     The fix is for a CAS90 component and does not require a
     cycle of DB2 in order to implement.
    Additional symptoms is hang with Autbnd06& 020.DBCMD
    ===========  lsk 3/28/05 ==============
    Slow hang poor performance of DSNTIAUL when using  SPIFFY
    (non IBM TSO/ISPF adendum product ) Batch job . Running
    DSNTIAUL under IBM's TSO batch program runs normally.
    ======================= lsk 3/03/05 ==========================
     Symptoms: abend0c4 in dsnvdlc dsnvialc or ABEND0C4 pic10 module
     unknown also ABENd0C1 00000001 DSNSCON +028E
      Problem caused by having  module DSNXGRDS in SDSNEXIT due to
      a third party software .  Deleting module from SDSNEXIT
      corrected the problem.
    ============lsk 2/22/05 ===============================
    ABEND04E 00C90101 C=810 r810 DSNIPPHO:2003
     rc00c90101 DSNIPPHO 2003 erqual2003
     DSNI014I -DST2 DSNIPPHO DATA IN USE DURING ABEND
             REASON 00C90101
             ERQUAL 2003
             TYPE 00000302  ( also could see TYPE 00000303 )
             NAME PSMADMO .PTTBL .X'00001414'
             CONNECTION-ID=TSO
             CORRELATION-ID=C33KDV
             LUW-ID=MEIJER.DST2APPL.BC791E80FD88=0
    You can use DSN1PRNT to format the header page x'0000'.
    Check to see if garbage is at x'0800' - x'0A0F'.
    CDB about their technical bulletin
    TB180 dated August 26, 2004
    for CDB's solution and  how to find problem and REPAIR
    the garbaged header page
    =================== rjl 02/03/05 ===============================
    Overlay of DB2 control block in common storage. ecsa csa erly
    Please contact the verdor Informatica for PowerExchange fix.
    =================== LSK 01/28/05 ============================
    ABND=04E-00E20017 DSNSTACK+0350 with Reg8 not on double word
    boundary. DSNSTACK at UQ54498 and customer was doing Runstats
    processing. Ca module *CASR230K 10/05/04 was not following the
    rules for STACK storage when making calls to DSNXKAL.
       CA fix is TE49570.
       04e s04e 00e20017 rc00e20017 DSNSTACK 0350 350 R8
    =================== 12/14/04 lsk =====================
    COMPON=SSI,COMPID=5752SC1B6,ISSUER=IEFJSARR,MODULE=IEFJRASP,
            ABEND=S0E0,REASON=0000002E,SNAME=DBXA
    Csect name: IEFJRASP System abend code: 00E0 reason code:
    0000002E
     abend00e0 rsn2e rc2e abend0e0 with MQ DB2 MIM
    found an eyecatcher module ( MIMETFIVTPCF4.6 ) in the dumps.
    This module belongs to MIM, a CA product. MIM PMR #13853831
    The MIM fix, TD46065, has resolved the problem.
    The fix addresses problems z/900 hardware and z/os 1.6 driver
    level 55.
    =================== 12/17/04 rjl ===============================
    We have also seen the abend0e0 rc2e for CA ENF/DB2.
    The fix number is TE49563.
    ================ 9/22/04   LSK ============================
    Candle fix QD2I224
    Abend04e 00E50079 rc00e50079 DSNVSR +1262 1262 or
    pic11 DSNVRDAG +0256 0256 256 or pic04 DSNAPRHX + AD2
    Stored procedure which was looping and exceeding ASUTIME .
    Possible Messages:
    MSGO21916 ABEND0C4 THREAD ALLTHOUT DSNAPRHX
    *DSNV086E - DB2 ABNORMAL TERMINATION REASON=00E50054 msgdsnv086e
    *DXR167E PRLM001 IRLM HAS DETECTED A DELAY IN COMPLETION
              OF ASID00E1 PROCESS  msgdxr167e
    DXR168I PRLM001 DELAYED PROCESSES NO LONGER DETECTED msgdxr168i
    The save area pointed to by reg13  in SKB, seemed to be overlaid
    Also abend0c6 because thread in DBM1 branched to PSA .
    Might abend in DSNTFRCV - recovery routine. Overlaying ACE and
    EB control blocks .
    Candle fix QD2I224 <===== for  ALL OMEGAMON II FOR DB2 USERS
    ABEND OCCURS WHEN RETRIEVING ALL ACTIVE THREAD INFORMATION.
    WHEN POPULATING THE ALLTHOUT TABLE, AN END OF  TABLE CONDITION
    WAS NOT BEING PERFORMED RESULTING IN DB2 ACE CONTROL BLOCKS
    BEING overlayed .
    
    
    ===================7/6/04     JAK    ==========================
    ABEND0C4 LOC=DSNXGRDS. DSNXERB( UQ85919 ) +0B02 due to wild
    branch when called by CA module  ITH$ENTY
    ABEND04E rc00E2000D DSNSFBK +6C2
    Caller is DSNLZS00 at UQ76490
    R11 has the inavlid Block which showed the storage overlay by
    the BMC .  overlaid overlays abend0c1 s0c4 s0c1 abend0c1
    Module name 'CTOX' by New Dimension Software Ltd - belonging
    to BMC Software.  Here's a snippet:
    | ........CTOX...   | NTROL-O, REL 6.  | MENSION SOFTWAR
    | ...Y......}....   | .02   LICENSED    |  LTD. BO1234  *
    | ..CTOSSI   - 10    | ATERIAL - NEW D  | **.............
    | 31/02 10.40 - C
    BMC informed that PA11525 has been marked PE and PA12887 is
    the PE HIPER fix. control control-o
    ============================= 8/18/04 KLK ======================
    abend04e rc00e2000d dsnsfbk +6B6 and other data sharing member
    received abend0c4 pic10 dsnvxr +1904 , then db2 crash w/
    rc00e50727 00e50727
    .
    The invalid block being freed has been overlayed by the OMIIDB2
    oem Omegamon perfm monitor and the customer reported the prob to
    Candle and informed that they applied QD2I244 for Omegamon db2
    v5.2 which appears to resolve this overlay prob.
    But this introduces an abend18A prob in Omegamon db2 which is
    being looked at for now.
    Customer closed this pmr for the overlay prob.
    ===================== 8/24/04 JAK =============================
    COMPON=RACF,COMPID=5752XXH00,ISSUER=DSNX@FRR,MODULE= DSNX@XAC
    ABEND=S00C4 REASON=00000011 L=000051A4
    Dump shows 0C4  irrrfc20+C66  because of bad R7=008CFD50
    XAPLACEE = 008CFD50
    DSNX210I  DB2x DSNXACAE - ACCESS CONTROL  064
    ...
    problem fixed by CA XMANAGER ( DETECTOR address space )
    CA fix for this problem is embedded in UXMD050
    ================== 8/30/04 MMM ============================
    INCORROUT - data with NULLs rows not found
    Symptom: V620 FLASH - When Generating Null Values,
    LOADPLUS Loads Incorrect Data
    Fix: BMC LOADPLUS for DB2/6.2.00
    Failure ID: 362692
    Resolution ID: 135542
    ================================================================
    ============10/29/2004 KLK =====================================
    Abend0c4 rc=0 seen from dsnl027i msg with no dump and no logrec
    info. Set a slip to capture the dump of abend0c4.
    PSW in the dump showed the code is in OEM product COMPUWARE
    XPEDITER .
    | .........0A.XPED
    | ITER/TSO07.02.00
    | PRIXPDB2PCR 15.3
    | 8 20030214 COPYR
    | IGHT (C) 2003, C
    | OMPUWARE CORPORA
    Below is the OEM Vendor fix and apply process:
    HOLDDATA ? CT1069457
    XTB0185
    IF YOUR SITE USES THE XPEDITER/TSO STORED PROCEDURE INTERCEPT
    FOR DB2, YOU MUST DO THE FOLLOWING AFTER APPLYING THIS PTF.
    After applying this PTF, execute the XPEDITER/TSO DB2 Stored
    Procedure Intercept Installation Utility specifying
    1. "DEACTIVATE"  to deactivate the Stored Procedure Intercept
    2. "MAINTENANCE" to update the Stored Procedure Interface
    3. "ACTIVATE"    to reactivate the Stored Procedure Intercept
    For more information, see "DB2 Stored Procedure Intercept
    Installation Utility" on page 4-5 of the XPEDITER/TSO 7.2
    Installation Guide.).
    .
    XTB0188
    After applying this PTF, an IPL should be scheduled.
    This will force a new fresh copy of Xpediter control
    blocks, including the Xpediter trace table. The
    normal install of the Xpediter Stored Procedure
    intercept can be done after the IPL.
    For more information, see "Activate the XPEDITER/TSO DB2
    Stored Procedure Intercept" on pages 4-4 thru 4-5 of the
    XPEDITER/TSO 7.2 Installation Guide.).
    =============================================================
    ==============KLK 11/08/2004 ================================
    pmr 65214,500 dsnl027i with abend052 rc00000000
    Logrec showed the following sequence:
    abend0c4 pic10 DT$DIXRC from PTXMAN CA detector monitor code
    abend052 rc00001212 with the same EB (Reg6)
    .
    Abend052 is a victim of the CA abend0c4.
    Customer received the CA fix UDTD216 and informed a good testing
    result with the CA fix to stop the abend052.
    ================== 12/07/04 rjl ================================
    CSA below the line in the db2 mstr address space with getmain
    from dccmgetm for sp241. Storage show the eye catchers sm1 skb
    dcctidcm. The product is BMC data collector.
    Fix number R185858 is available from BMC.
    =================== 12/21/04 rjl ===============================
    If the AX value is not 00 when an allied task connects to DB2 a
    AX value will be reserved and set for the allied address space.
    This value must not be changed while DB2 is processing on behalf
    of the allied task.
    If it is a ABEND0D7 will be issued when DB2 issues a cross
    memory instructions like SSAR. The SSAR was issued from DB2
    csect DSNYALLI.
    There is a small timing window where DB2 and a non DB2
    application can both issue a AX extract and get a zero value
    indicating a AX value is not set.
    Both applications will then RESERVE and SET a different AX value
    for the allied address space.
    The first application to do so will later fail due to the AX
    value being changed by the other application.
    This has been reported with the other application MQSERIES.
    The connection request from the allied task should be reissued.
    ================ 01/04/2005 KLK ===============================
    PMR 34647,7TD reported running DB2 utility getting SPIN LOOP
    in RSM IAXUA to get real storage frame.
    Storage getmained was in SP3 Key7 in 64 MB chulks under OEM
    product of SYNCSORT.
    SYNCSORT informed that EW5892 will reduce the amount of storage
    used by the DB2 sort. So, EW5892 is the fix to this SPIN LOOP
    / Storage prob with DB2 utility run.
    
    ===================== 2/1/05 JC ======================
    PQ99095 - the symptom RC00D70020 in DSNPXTRC is seen when DB2
    is running in z/OS 1.5 or above with BMC Mainview.
    ==========================================================
    ===================== 3/4/05 EK ==========================
    Abend04E 00C90101 RC00C90101 DSNKSALO 2003 or 2001
    because the shift value in the OBD (OBDINSHF) does not
    match the shift value in the index header page (HPGINSHF).
    .
    This problem occurred with partitioned tablespaces which had
    DSSIZE 8G (see PMR 56695,211,788 and related PMRs for more
    details).
    .
    The problem was caused by an error in OEM Reorg utility.
    The vendor (Infotel) have provided fixes for InfoLoad and
    InfoReorg:
    Version 4200: PTF UT420015
    Version 4100: PTF UT41009P
    ==========================================================
    ==========03/23/2005 Kai-Li Kow KLK ======================
    pmr 57777,005 spin loop abend071 rc30 DT$DIXRC CA PTXMAN
    Detector. Customer received the following fix from CA to fix
    the prob, ie.
    UDTE140, UDTE143, UDTE146, UDTE149, UDTE151, UDTE152
    ===========================================================
    86088,49R,000 .. QYU
     DB2W,ABND=0C1-00000001,U=GNLINTW ,C=XYR00.710.RDS -SQL
     ,M=DSNTFRCV,PSW=070C0000808E0AEA,A=00C5
    Verbx Logdata shows 2 ABEND0C1s have also taken place
    previously. Inspection of both of those ABEND0C1
    logrec entries shows REG 14: x'10715016' pointing
    into Computer Associates Module after Branch and
    link 14,15 instruction.
    ncluded the eyecatcher for the module below:
    
     |DT$DIIC7V05.0010/12/0418.03 MVS4|
    |30DB2710(c)1993-2004 Computer As|
     |sociates International Inc.     |
    it was fixed by two Detector's
    fixes:UDTD226 and UDTD236.
    ============GPUT 4/27/05   Georgann Putintsev =======
    z/OS 1.4 DB2V8 - Unable to Connect to DB2 Connect
    due to OEM/Vendor Product.  Errors include:
    DSNL027I  -DBU1 SERVER DISTRIBUTED AGENT WITH  441
               LUWID=CC410364.FA18.BCE3BB60C33E=1467
               THREAD-INFO=WLK:M02HOST:WLK:*
               RECEIVED ABEND=0C4
               FOR REASON=00000000
    DSNL028I  -DBU1 CC410364.FA18.BCE3BB60C33E=1467  442
               ACCESSING DATA FOR
                 LOCATION 204.65.3.100
                 IPADDR 204.65.3.100
    .
    ABEND0C4 RC0000003B DSNXEPM +4D79-- 03/07/05 UK01215
    .
    Using Visual Explain via DB2 Connect msg:
    [SQLSTATE=40003 - [IBM][CLI Driver][DB2] SQL30020N Execution
    failed because of a Distributed Protocol Error that will affect
    the successful execution of subsequent commands and SQL state-
    ments:  Reason Code "1232".
    .
    Our DB2 RDS module DSNXERT should only be called by a DB2
    module, normally DSNXERD.  A vendor product TMON / SQL Analyzer
    from Allen Systems Group, Inc. intercepts DB2's RMFT (resource
    mgr function table).
    .
    The latest safe PTF level for SQL/Analyzer is TE02278 running
    with DB2 V8.1.  User's can turn off SQL/Analyzer by specifying
    SQLC=N parameter in their TMON for DB2 startup PARMs.  This is
    the member pointed to by the TMDBPRMS DD ...startup jcl.
    ..
    Please stay at TE02278 until SQL/Anlayzer becomes more STABLE.
    =------------------------------------------------------------+
    ================= 05/04/2005 JC ============================
    ABEND0C4 DSNPSYSP with OEM FASTVSAM.
    The FASTVSAM fix is EWV1442. Recyle DB2 after applying OEM fix.
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • can informational apar on OEM vendor product fixes
    for DB2
    

APAR Information

  • APAR number

    II13897

  • Reported component name

    PB LIB INFO ITE

  • Reported component ID

    INFOPBLIB

  • Reported release

    001

  • Status

    CLOSED CAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2004-07-06

  • Closed date

    2004-09-22

  • Last modified date

    2007-12-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
07 December 2007