Error description

  • When tso user issues get_debug command, supplying his own user
    ID as the high level qualifier, receive following errors:
    IOAC109E File allocation error. Error code FFFF9700 info code 0
    and on syslog:
    ICH408I USER(OSASF   ) GROUP(RACFPROC) NAME(SHAW, D.J. (DAVID)
      MARTIN.QUERY.DEBUG.MESSAGE CL(DATASET ) VOL(*BLANK)
      DEFINE - INSUFFICIENT AUTHORITY
    
    SOLUTION:
    User OSASF must have ALTER access to tso user's datasets (the
    tso user profile user.*).
    .
    General OSA/SF RACF guidelines:
    - The OSA/SF started procedure must have ALTER access to the
      calling user's dataset profile, or ALTER access (or
      equivalent) to the dataset profile of the user/group for any
      HLQ passed by the user for dataset allocation.
    - A user must have at least READ access for any other HLQ passed
      for dataset allocation.
    .
    For Example,
     To create the RACF dataset profile issue the following RACF
     Commands:
       ADDSD 'MARTIN.*' UACC(NONE)
     -Or, If RACF Enhanced generic Naming is Active (EGN),
    ADDSD 'MARTIN.*.**' UACC(NONE)
    .
    Then issue the appropriate Permit:
       PE 'MARTIN.*' ACC(ALTER) ID(OSASF)
    -Or, If EGN is Active
      PE 'MARTIN.*.**' ACC(ALTER) ID(OSASF)
    .
     Refresh the Class:
       SETR GENERIC(DATASET)REFRESH
    .
     You can then verify the existence of the covering profile:
       LISTDSD DA('MARTIN.QUERY.DEBUG.MESSAGE') GENERIC
     Should then return with:
       INFORMATION FOR DATASET MARTIN.* (G)
     -Or, If EGN is Active
       INFORMATION FOR DATASET MARTIN.*.** (G)
     . . .
     Note:
      Either providing the OSASF Started Task with the RACF TRUSTED
      Attribute, or granting RACF OPERATIONS authority to the
      associated useridwould allow OSASF to define the TRACE
      datasets with 'any' user's HLQ, without the above dataset
      definitions. Keep in mind that the TRUSTED and OPERATIONS
      settings should be okay'dwith your security folks.
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    II13591

  • Reported component name

    V2 LIB INFO ITE

  • Reported component ID

    INFOV2LIB

  • Reported release

    001

  • Status

    INTRAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2003-05-09

  • Closed date

  • Last modified date

    2003-05-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
09 May 2003