II12350: AVOID MRQ V3 LINKEDIT CC=004 AND FMQINSRT S0C1 ABEND

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • INTRAN

Error description

  • If MRQ V3 was re-linked outside of SMP:
    1) link-edit will give condition code 004 and message-
      IEW2454W 9203 SYMBOL AIBTDLI UNRESOLVED.  NO AUTOCALL (NCAL) S
      2) FMQINSRT will ABEND with S0C1.
    

Local fix

  • MRQ V2 did two linkedits to get the insert module
    (FMQINSRT) into the distribution library:
      1. to get the textdecks linked into a temporary library
         as FMQINSRT (with a linkedit error message saying AIBTDLI
         was not resolved).
      2. to pull the FMQINSRT module from the temporary library,
         and the AIBTDLI module from the IMS RESLIB into the
         permanent distribution library.
    The latest level of SMP does not allow multiple linkedits,
    so the second linkedit job was not shipped with MRQ V3.
    
    This situation required MRQ V2 to be re-linked after
    certain IMS maintenance was applied.
    The currently supported MRQ V3 does not need to be
    re-linked after IMS maintenance is applied.  MRQ V3
    uses the IMS AIB interface to avoid this necessity.
    DO NOT RE-LINK MRQ V3 OUTSIDE OF SMP.
    
      1) link-edit will give condition code 004 and message-
      IEW2454W 9203 SYMBOL AIBTDLI UNRESOLVED.  NO AUTOCALL (NCAL) S
      2) FMQINSRT will ABEND with S0C1.
      ** The quickest and easiest fix is to re-link FMQINSRT
         adding 'INCLUDE SYSLIB(AIBTDLI)' in the link-edit step.
    

Problem summary

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    II12350

  • Reported component name

    V2 LIB INFO ITE

  • Reported component ID

    INFOV2LIB

  • Reported release

    001

  • Status

    INTRAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2000-04-12

  • Closed date

  • Last modified date

    2000-04-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 April 2000