Error description

  • This info apar will be used to document and make searchable
    problems associated with OEM products affecting ISMF, SMS and
    dfp and dfsms, as these errors come to the attention of level2.
    When possible, fixes, including maintenance or release numbers
    or parameter and option changes will be included. For details
    the customer may need to consult with the OEM vendor whose
    product is referenced here.
    1) Contact SYSNCSORT for ew4490 for syncsort release 3.4
       any maintenance level, or release 3.5 prior to the
       3.5E/TPF4A level.
    
    2) ABEND0C4 in IGDACS00 at or near offset x'1980'.
       Analysis of a dump revealed the ABEND0C4 in sms
       code was preceeded by abend0c1 with PSW pointing
       into the cvt plus x'D6'. The 0c1 occured while
       oem product Top Secret was processing a racroute
       or racdef on behalf of OEM product NDM by way of
       SMS acs routines.
    RESOLUTION: Top Secret has a parameter that needs to be
       set to permit multi-tasking products such as NDM to
       process multiple security access requests concurrently.
       If this parm is set to "single thread" such requests
       the abend0c1 can occur, followed by the abend0c4.
       Contact OEM Computer Associates vendor for specifics
       of the parameter and its setting.
    3) MSGIGD308I with an abend0c4 in ACF2 code at
       ACF00SVA + x'5D6' approximately.
    RESOLUTION: ACF2 apar G038602 with fix TA1622A.
    
    4) msgigd17040i rc168 with dadsm diagnostic information
       x'040e0400' indicating ds already defined.
    This problem reported in conjunction with ACF2 release
    6.0. Customer reports CA recomends applying release 6.1
    to incorporate fix.
    5) Abend0c4 in CSECT IFG0RR0E + 796.
     The fix is APAR TR41027 for Thruput Manager from MVS Solutions.
     It fixes S0c4 abends in DTMOMX08 attempting to start ASCHINT in
     MVS 5.1.
    6) msgigd300i an abend occurred during sms
       processing, abend system code=0c1.
       Abend0c1 in IEC0SCR1.
       OEM MIM fixes:
       The MIM APARs that are needed:
            SD35381
            SD35374 (NEEDS SD35381 AS A PRE-REQ)
    7) SMS hangs during IPL with msgigd300i
       JOB MASTER * MASTER IS WAITING
       FOR SMS ADDRESS SPACE TO INITIALIZE
    Problem isolated to OEM products BBXS and CSMON,
    both from Boole and Babbage. B&B fix number BAB1160
    resolves problem with pre-req fix BPB1114 or BPB1170.
    Changes to subsystem name table may have been a possible
    contributor to this problem.
    8) ABENDE37 RC08 when going into extents on an sms managed
       volume that should have plenty of space. Also receives
       MSGIEC614I RC00 Diag Info 04034379.
       OEM product SAMS ALLOCATE ( A.K.A. VAMS ) takes space
       parm coded for allocation and assumes it is in kilobytes.
       This parm can be tracks or cylinders among others. When
      SAMS passes the value it may have taken a cylinder value
       of 10 ( for instance ) and made it 10 kilobytes, thus
       leading to abende37 abendd37 or abendb37.
    8-a) ABENDE37 RC08 MSGIEC032I E37-08 IFG0554T trying to
         extend to another volume
         MSGIEC614I Extend Failed RC216 DIAG(044E0097) &/or
         RC00 DIAG(04034379)
         ABEND0C4 in DSR0020 at x'DF2' MSGDSR1502
         FIXED by EMPACT SOFTWARE'S STOPX37 via fix #
         X3734P37 for Release 3.5.1
         STOPX37 description: If site is MVS 4.3 SMS SREDUCE
         Code is not invoked due to error in obtaining volunit
    9)  msgigd306i rsn5001 with logrec entry and detecting
        module IGDCNSAQ. Product JOB/SCAN.
        Diversified Software Systems zap to module D00ycom,
        csect d00ysms resolves error. ZAP number Z209392A.
        This ZAP is included in the 5.6.3A (and later)
        levels of JOB/SCAN and DOCU/TEXT
    9a) MSGIGD306I RSN5009 Logrec entries from IGDACS00
        and IGDCNSAQ when executing DOCUTEXT (DOCU/TEXT)
        code.  May also see ABEND878 in address space where
        job executing DOCUTEXT is running.  Flushing the
        job will eliminate the RSN5009 logrec entries.
    10) Loop in module IEFIIC during allocation of ds with
        LIKE= parameter. In most reported instances it seemed
        there was not space available on the chosen vol for
        the ds. Save area chains lead to stopx37 module
        DSR1600. Stopx37 fix number:
        It is X3735C47 and is applicable to release 3.5.2
        and higher. The fix checks for the "like=" parameter
        and will not attempt recovery if it is specified.
    11) Temporary ds's being treated as permanent by sms acs
        routines. ENDEVOR OEM product uses JCL like:
    //C1INIT03 DD DSN=&&REGENMSG,
    //            UNIT=SYSDA,
    //            SPACE=(CYL,(5,1)),
    //            DISP=(NEW,PASS),
    //            DCB=(DSORG=PS,RECFM=VBA,LRECL=137,BLKSIZE=23476)
       RACF errors or dynalloc error rsn970c or the ds may be
       managed as though it were permanent, not temp. ACS trace
       shows DSTYPE of perm, not temp. ENDEVOR MODs to the temp
       ds in such a way as to make it PERM.
       *********
       ADDENDUM: ENDEVOR is actually allocating this dataset as
        permanent (using an SVC99) using a a temporary dataset name
        format. The default name format is:
          SYSyyddd.Thhmmss.RA0.jobname.ddname
        BUT the High-Level-Qualifier can be changed from SYSyyddd
        to an installation-chosen qualifier by changing the MODHLI
        parameter in the Endevor default options table which will
        correct this problem.
    12) Running ASTEX product from Legent Corp may receive
       a rsn code 5002 rsn5002 "CONSTRUCT NOT FOUND".
       Problem can occur with ASTEX releases 1.7 or 2.0
       in shops with volsers of fewer than 6 characters.
       For release 2.0 ASTEX fix number F200131Z provided.
       Contact LEGENT for this fix or the proper fix for
       release 1.7. ( Per Mary Goettel, Legent software support).
    

Local fix

  • 13) An Authorized program (such as ROSCOE) fails a call
        to SMS because the JSCBAUTH bit is turned off by Sterling
        Software's VAM at release 5.0.4. Module VAMACS00 at x'3F8'.
        Problem is resolved at VAM 5.0.5 or via fix # 130493.
    
    14. PS-e extended format data sets. ABEND737 rsn04
        while extending single striped data set.
        msgiec027i iec027i iec027.
        OEM: Space Recovery Systems , Mitchem Technologies SRS
        OEM fix: DT00042 or move to release 1.2.4
    
    15)ABEND0C9 IGDVTSSP using FDR RECALL/RECOVER for VSAM
       Cluster.  Customer may see MSGFDR157 COMP=9116 CODE=00300
       Fix number: P-52.0633
    
    16) MSGIGD308I Data Set Allocation Request Failed - Data Set
        Owner nnnn Is Not Authorized to Create Data Set nnnn with
        Storage Class nnnn. Message issued invalidly.
        ACF2 fix number: GO34432
    17) MSGADR709E during logical copy of vsam linear ds to
        sms managed volume.
        MSGIGD17103I  CATALOG ERROR WHILE DEFINING VSAM DATA SET
                     RC140 RSN102 IGG0CLEM
        MSGIGD306I UNEXPECTED ERROR DURING IGG0CLEM RC140 RSN102
        MSGIGD17219I UNABLE TO CONTINUE DEFINE OF DATA SET
        Problem resolved by POOL DASD fix number PD331C09.
        or PD332C09 depending on POOL DASD release in use.
    
    18) ABEND0C4 IOSVSSCH after full volume copy when volume is
        left online to one system in multi-system environment.
        ASTEX fix number 75768
    19) ABEND0C4 IN IGG0CLEP + X'1C8' USING OEM DMS
        TO DEFINE VSAM KSDS.  IGG0CLEP ABENDS BECAUSE
        THE POINTER TO INDEX UCB ADDRESS LIST IS ZERO
        (CTGFVUCB).  THE OEM PRODUCT INVOKES SMS VIA
        SUBSYSTEM INTERFACE (SSOB) PASSING INTO SMS A
        SSSA(E) WHICH CONTAINS A POINTER TO CPL.
        RESOLUTION: THE OEM VENDOR PROVIDED A FIX:
          DMS REL 8.1.7 REQUIRES FIX SD31294
          DMS REL 2 REQUIRES FIX  SS00342
        DMS ADSSI001 INVOKED SMS IGDSSIRT VIA SSI.
    20) Running OEM product JCL CHECK from Computer Associates
        ( CA ) receive a jcl check msg that includes SMS
        reason code 5002 rsn5002. Fixed by JCL CHECK PTF
        GO78050 for release 6.2 at 9505 maintenance level.
    x) MSGICH408i msgigd306i rc8 rsn1026 indicating security
       authorization for ds allocation has failed, but the
       ds is allocated anyway. Later, msgigd17105i, catalog
       error rc56 rsn6 is received on delete.
       fix for OEM PROSMS(X37/II) release 3.4.2 is PR341P15.
    23) msgigd17101i rc6 rsn56 duplicate ds in catalog
        received along with dynalloc rsn970c. LOGREC fills
        with erep entries for this error as the program
        retries endlessly untill batch job cancelled.
        Solution:   OEM PROSMS fix number pr334p46.
    24) MSGIGD306I with rsn18038 and logrec entries
         "NEW HIT RATIO IS IN ERROR"
        This can be a h/w problem with OEM EMC dasd devices.
        EMC PATCH 5054 for microcode level 5060-3224 has resolved
        this problem for at least one customer.
    25) Abend047 executing IDCAMS with DCOLLECT option, TSO RECEIVE
        and finally failing in IEBCOPY.  Found that there was an
        OEM product turning off JSCBAUTH bit resulting loss of
        authorization to issue SVC107 (MODESET). The OEM product
        is PROSMS Version 3.4.1 ( the known fix is PR341P13).
    
    26) msgiec614i SCRATCH FAILED rc8 diagnostic information
        04094399 on delete of gdg. Product RUNTRACK from
        Computer Associates ( CA ) apar number RW73348 for
        release 3.1. Customer relates fixes for other releases
        were available. ( 1/31/96 ).
    27) ABEND0c4 in ACF2 module ACF9C000 at offset X'582'.
        Caused by ACF2 APAR G070545 fixed by ACF2 APAR
        G083718.  Instructions: 440FC59C 410C578
    28) MSGIGD306i rsn5001 with logrec entry witten by SMS rel 1c0.
        Issueing CSECT = IGDCNSAQ.
        OEM product OMEGAMON/SMS ptfs QDF2033 and QSB1109 fix
        this problem.
    ALSO*******
        Boole and Babbage products RESOLVE, CMF and MVMVS with
        BBX have the same problem. PTF BPB1170 provided by
        B&B.
    ALSO ***************
        B&B product Storage Guard Control ( SG-CONTROL )
        APAR number SC221P47.
    ALSO ****************
        FDR product ZAP number P-52.0697.
    ALSO ************
        MITCHEM's Space Recovery System, fix number DTS20058.
    Also known as DIF (Dynamic Install Facility) Mod DIF2091
    ALSO *************
        IBM RMF apar ow18557.
    29) msgigd17273i and msgigd17277i issued recursively
        ( 3600 times in the reported case ) for a batch
        job allocation using LIKE=.
        STOPx37 rel 3.5.2 and 3.5.4 fix numbers X3735C47
        and X3735C56. loop looping recursive looped.
        Other releases may also have fixes for stopx37.
        IGD17273i 17273 rsn17273
        Problem also reported for OEM product PROSMS.
    :
    30) IEB1057I VL GETMAIN REQUESTED 250K TO 1M BYTES.
        IEB133I MINIMUM REQUESTED STORAGE NOT AVAILABLE
        This problem was caused by an OEM vendor (BMC)
        (Product DATA ACCELERATOR NON VSAM).
        The eyecatcher was DPOCOPY csect in DPOMOCOPY.
    
    .   Resolution:  BMC fix number - P281547
                     for version 1.0.04 and
                     for version 1.0.05
    .
    31) Abend0c4 in IGDSSISM +x'66' with dump title:
       ISSUER IEFAB4ED,ERRCSECT=IEFAB434,COMPID=5272-SC1B4
            COMPON=DEVICE ALLOCATION-COMMON ALLOCATION
        OEM fix number L1H067Z from STORAGETEK for HSC
        product reported to solve the abend by a customer.
        Also FDRABR fix Z520633 has been reported, but not
        confirmed to resolve this problem.
        In several cases the abend0c4 in IGDSSISM has been
        preceeded by less than one second by an abend0c4 in
        IGDVTSAV. The S0C4 in VTSAV caused the S0C4 in SSISM.
        OEM fix from MITCHEM systems provided via ZAP resolves
        the s0c4 in VTSAV. OEM product is " DIF ". Eyecatchers
        in dump indicates "COPYRIGHT DTS SOFTWARE". Contact
        Mitchem for ZAP details.
    32. MSGIGD306I RC8 RSN1026 for GDS G0000V00.
        IGD308I - Dataset allocation request failed -
        RACF Function: RACDEF for
        Data set: dsname with rc=08 and reason code 00
        IGD306I Unexpected error during RACDEF processing
        Return code 08 reason code 1026
        The module that detected the error is IGDACS00
        SMS module traceback - ACS00 IDMCD IDM00 SSIRT
        Symptom record created, ID is IGD00000
        ACF99913 ACF2 violation-08,10,................
        CA-APAR tracking number TA2376C with SYSMOD GO82041.
    33) ABEND047 in batch job allocating SMS managed DS's.
        Analysis of dump shows abend047 in B&B csect
        SMSXACS00, part of PROSMS product. Zap number
        PR351P52.
    34. ABEND073 ( CML lock heirarchy violation ) running SMS
        with ASTEX release prior to release 2.1. ASTEX prior
        to release 2.1 does not support 4 digit UCB's.
    35. May see ABENDB78-RC08 when PROSMS CSECT SMSXSSIRT
        EYECATCHER PRSM34 issues SVC78.  OEM VENDOR owner
        Boole/Baggage has provided zap PR342P67.
    36. MAY see RC16 RSN6103 (6103) - ERROR DETECTED BY SSI.
        Error occurred when using ISMF with CDS name 'ACTIVE'
       to retrieve data from the SMS configuration.  Failure
        detected by SMS CSECT IGDCSCNS when IEFSSREQ macro
        issued.  Error caused by PROSMS not being initialized
        completely.  Recycling PROSMS resolved problem.
    37. Using STK SILO HSC ds allocations intended for tape
        in ATL are mounted to non-atl tape devices instead.
        STK PTF L1H06VS.
    38. IRA200E AUXILIARY STORAGE SHORTAGE in user address space.
    Control blocks left in storage may contain the following eye-
    catchers: IGDSGD, IGDMCSC2, IGD101I and IGD17101I.  SMS builds
    these messages and returns them to the caller, it is the cal-
    ler's responsibility to free these message areas when no longer
    needed.
    Normally SMS's callers for JCL data set allocations will be the
    ALLOCATION component.  However, in this case an OEM product is
    intercepting the return to ALLOCATION to check the SMS RC/RS
    code, and may redrive the ALLOCATION will be redriven.  When
    the allocation is redriven by the OEM product, storage contain-
    ing the initial messages is left unfreed.
    The customer provided the following update regards a fix she
    received from the OEM VENDOR:
    
    "OEM fix solved the problem.  FYI the vendor is DTS Software
     (formerly Mitchum Technologies) and the product is Space
     Recovery System (functionally like StopX37).
     We needed release 2.1.14 with a zap on top of that."
    

Problem summary

Problem conclusion

Temporary fix

Comments

  • closing to make updates available to world trade
    

APAR Information

  • APAR number

    II08178

  • Reported component name

    V2 LIB INFO ITE

  • Reported component ID

    INFOV2LIB

  • Reported release

    001

  • Status

    CLOSED CAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1994-09-06

  • Closed date

    1997-01-15

  • Last modified date

    2004-12-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
14 December 2020