APAR status
Closed as canceled.
Error description
TPINFO VTAMINFO 568508501 569511701 R431 R404 R101 r201 This information APAR contains definitions of several LAN return codes that were not available when OW00297 for VTAM V4R1 and OY64182 for VTAM V3R4 were written. Those APARs document new messages MSGIST1411I, MSGIST1412I. and MSGIST1430I. Refer to those APARs or to the PTF cover letter for the APAR for your VTAM release. The messages are also in the VTAM V4R2 Messages and Codes, Chapter 12. Several LAN return codes are defined with a x'FF' in the first byte. These return codes were not specifically associated with the return code categories defined in OW00297 or OY64182. They are documented here and will be included in the VTAM Messages and Codes in the future. OTHER LAN RETURN CODES: o CODE FF02 - Duplicate command - This completion code is returned if a connect request is received for a link station, while a previous connect request is still in process. o CODE FF0C - Command cancelled, invalid version number - This completion code is returned if the primitive contained an invalid version number. o CODE FF4C Sequence error - This completion code is returned if a Deactivate_SAP or close request is received, while other SAP or link commands are still in process. Wait for the commands to complete, then re-issue the close request. o CODE FF4F - Invalid remote address - This completion code is returned, if an OPEN_STATION request is re- ceived with the remote MAC address parameter high bit of the high byte set to 1. This indicates a group address. A group address is not allowed to be speci- fied for this command. VTAM Hint: If you are running VTAM V4R2, a possible cause of code FF4F is that DLCADDR is specified in the definition for a D/T3172. The 3172 does not currently support DLCADDR. DLCADDR is a VTAM V4R2 parameter on the PATH definition statement for a switched major node. o Code FF76 - A frame reject (FRMR) was sent to the DSPU. The FRMR sent is the result of either: - MAC frame invalid control field. - I-field contains data that is not valid for that control field; for example, an I-field was included in a SABME. - The received I-field length exceeds the buffer capacity of the receiver. - LPDU control field sequence number error. - the FRMR response I-field is not 5 bytes in length.
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
Information item.
APAR Information
APAR number
II07842
Reported component name
V2 LIB INFO ITE
Reported component ID
INFOV2LIB
Reported release
001
Status
CLOSED CAN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
1994-04-28
Closed date
1994-04-28
Last modified date
1994-05-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
14 December 2020