  • *************** CONTINUATION OF II07438 *****************
    .
    See also II08212 II07438 II07757 II08264 II08762 II09608 II10937
    This info APAR lists known third-party (OEM) problems in DFP
    data management components: non-VSAM o/c/eov, sequential access
    methods, linkage editor, and PDSE.  Where possible, OEM fix
    numbers are listed.  It is by no means a complete list.
    ABENDA78-18 AREA TO BE FREEMAINED WAS PAGE FIXED
      Module IEWFETCH issues a freemain for an area of storage that
      was page fixed.  This occurs because TLMS by Computer
      Associates issues several page fixes without the corresponding
      page frees.  This problem is fixed by T5XD394 and TDXD399.
    .
    HANG DURING IDCAMS PROCESSING AND A BMC MSG INDICATING ABEND
    IN OBTAIN. The problem was caused by BMC DATAPACKER OS when the
      data set was allocated on the cylinder of a 3390-3.  An old
      I/O module was responsible and the vendor provided a zap to
      correct the problem.
    .
    ABEND378 RC24 in BLSQFREE+'34'
      Storage is being freed invalidly out of IFG019RA +'7F6' due
      to invalid pointers in the DEB.  CA's VSAM Transparency 2.1
      product (DBVT) is using the protected DCB.
      The fix number is G022213.
    .
    MSGIEC704A NOT ISSUED AFTER FOLLOWING GUIDELINES IN II06795.
       OY47798 added support for the use of 3490E 36-track tapes
       to be used as scratch tapes on 18-track 3480 devices.
       II06795 describes guidelines for implementing this support.
       CA-TLMS customers in this position should make sure
       the following APARs are installed.
       GO27018 - Hook H93A4H2 - support for IFG0194K at UY93456.
       This information is applicable to CA-TLMS version 5.3
       genlevel 9108TL530.
       SPSS = Statistical Package for Social Science
       MIGM16KT,SPSS41,330,DA,   ,READ  ,WRNG.LEN.RECORD,
       000000A1000A0D,BSAM
       Contact SPSS OEM vendor for fix.
    .
    HANG IN IGG019AR SVC01
        IGG019AR issues svc01 and goes into a  wait.
        ABEND-AID error message:
        CCAASNP05 - CCASNAP DCB NOT OPEN AT THE TIME
                    THAT CSATODP STOPS UPDATING.
        The ABEND-AID PTF number is CC12081.
    .
    ABEND0C4 IECVEXCP+x'E34'-DCB ADDR POINTS TO UNAVAILABLE STORAGE
      Program "SELCOPY" which was entered via LINK macro, opened a
      file using a DCB embedded in the program and exited without
      closing the DCB. CSV then called FETCH to freemain the
      program storage but the DCB was no longer available, causing
      a program check in EXCP.  The problem was with SELCOPY and
      the vendor COMPUTE (Bridgend)Ltd provided the following
      ZAP #3:
      When a DOS type /* card is included at the end of SELCOPY's
      control cards on SYSIN, and SYSIN is a file rather than a
      DD * stream, SELCOPY treates the /* as a logical EOF, but
      fails to close SYSIN, which can result in an 0C4 or 0C3
      abend at task termination when the operating system attempts
      an automatic close on SYSIN.
      The ZAP #3 is:    SELCOPY+012BE4 VER=4780,5082  REP=4780,5076
    
    ABEND0C6 IFG0552B
      An ABEND0C6 in IFG0552B at UW03774 occurred after an
      MSGIECTMS3 saying the tape volume is not scratch.
      Contact CA-1 for the fix.     5/3/94
    5/5/94
    Datasets with the HLQs of IVPSMS and IVPSMS1 are treated
    differently by each of two MVS lpars.
    Resolution: Apply TA1234B fix for OEM CA-ACF2.
                                                   x
    Hang in IEBGENER processing of concatenating 2 empty
    data sets.  Hang is caused by a wait issued by IGG019BB.
    Problem is caused by OEM Product Performance Solutions
    by Softworks.
    .
    ABEND0F4 in IGWBIEX1:
     ABEND0F4 occurred in IGWBIEX1 (HDP3330) at offset '8C4'
     with directory I/O error RSN150BC008 attempting
     to read the first 5 PDSE pages from DASD during PDSE connect.
     The IOSB pointed to by IGWBIEX1 autodata shows
     incorrect length with a residual count of 'F00'
     and indicates the physical blksize is 256 bytes and this
     is not a 4096 byte PDSE record.
     Found the VOLSER & TTR of format1 DSCB in the PDSE token (VSGT)
     and LISTVTOC shows "I" under SMS.IND (system-managed storage
     attributes) indicating DS1PDSE is set in the data set
     associated with DSCB field C-H-R converted from TTR.
     LISTVTOC indicates this data set has a creation date
     of 1985.294 that was prior to the first DFP release of PDSE's,
     therefore the DS1PDSE bit has been overlayed.
     Customer is using OEM products from "FDR" and
     "Computer Associates" and we do not know what program
     overlayed the DS1PDSE.
     As described in DFP PDSE info apar II04480, the format1 DSCB
     at offset X'4E' is a RESERVED field.
     Since PDSE's must reside on system-managed volumes, LISTVTOC
     also shows "S" under SMS.IND and the format1 DSCB
     offset X'4E' equals X'88' when DS1PDSE is set.
     The data set was restored to non-PDSE and system-managed
     via SPZAP of offset X'4E' to X'80'.
       5/5/94 - 566528462
       ABEND212 in DSR0015(owned by STOPX37)
       Contact STOPX37 for the fix
    MSGWER268A received while executing EDGRPTD. Contact SYNCSORT
    for EW3703 for releases 3.4 and 3.5 only.
    
    ABEND378 RC12C MSGIGD300I IN MOD IGDZILLA
    MSGIGD080I
    ACF2 refresh of SAF records clears the getmained area
    .
    Incorrout using DISP=MOD
    When OPEN DISP=MOD, records were being appended to the end of
    the extent rather than after the EOF mark.  Contact SYNCSORT
    for EW3390 for Rel 3.3 or for Rel 3.4 prior to the 3.4E/TPF4
    level only.                            5/18/94
    .
    MSGIEW4007 - DIRECTORY ENTRY IS INVALID FOR A LOAD MODULE -
    This message can be issued if DELTA IMS or LOCAL COPY PLUS
    for IMS is being used. Zaps are available, if these products
    are being used, from BMC. BMC problem tracking number for
    DELTA IMS is # 162409. Tracking number for LOCAL COPY PLUS for
    IMS is # 207582.
    .
    MSGIEW2900T E913 RC 4D2B2900 6604B000 on IEBCOPY of Load
    Library PDS to PSDE or when Binding module : RSN4D2B2900
    This can happen when an ESD label (LR) is pointing to another
    label or null section.  A label must point to a CSECT (SD)
    This is a problem with the module source or compiler that is
    used.  This is usually discovered when binding an old linkedit
    module with the Program Management Binder.  Can be OEM or user
    application.  The ESD will need to be corrected in the source
    or compiler.
    .
    ABEND106-0E Reason 20 - Error Converting TTR - could be
    issued if PDSMAN is active. To confirm, deactivate PDSMAN
    and rerun the job.
    .
    MSGIKJ58207I - 'Unable to RENAME dataset
      OLDDSN'+ RENAME ERROR CODE 8
      Caused by OEM product POOLDASD not releasing
      the ENQ on the TIOT.  Fix is PD941302
    .
    MSGIEC135A after MSGIEC501A and using oem security package
    ACF2.  IEC.TAPERING needs to be defined to the security
    product.
    Using the SAFPROT define CLASSES(FACILITY),include in SAFMAPS
    a pointer for FACILITY to a resource, (IE: XXX).  Within
    RESDIR.  Within RESDIR, make the resource XXX resident.
    Define the key for IEC.TAPERING to allow the read.
    EXAMPLE:
     sysid / SAFPROT.LOC CLASSES(FACILITY) .........
     sysid / SAFMAPS MAPS(XXX/FACILITY .......)
     sysid / RESDIR TYPES(R-XXX .........)
     $KEY(IEC.TAPERING) TYPE(XXX) UID(*) ALLOW
    .
    A compile of the rules are required or restart of the security
    software, normally known as an IPL.
    .
    IEC999I (msgIEC999I) IFG0196W ABEND0C4 RC10 in LLA during ipl
         ABEND0C4 was actually occurring in IFG019RD + x'1D4' where
         we try to restore the regs to the original values.  Problem
         was with OEM tape management system called ZARA from ALTAI.
         Installation instructions were "REINSTALL US EVERYTIME THAT
         YOU CHANGE ANYTHING" which was not followed.
    .
    ABEND0C4 IGC00020 CLOSING A VTAM ACB
         An ABEND0C4 in IGC00020 + x'2E6' on instruction 910FB000 is
         received when testing a non-existant DEB in reg11.  Problem
         was caused and fixed by OEM vendor.  'SWITCH' fix 4.0.67
    .
    IOS000I IEC512I TAPE LIBRARY NOT HANDLING UNINITIALIZED 3490E
         Uninitialized 3490E carts were not getting relabeled.
         CA provided fix # 2301528.
    .
    IEC148I (msgIEC148I) ABEND713 RC04 IFG0196Q
       Abend713-04 is received when concatenating input
       sequential data sets using IEBGENER.  The problem is being
       temporally bypassed by TLMSII who suggested changing
       the following parms to TLMSII: .
       DBLDRIVE=NO     to   DBLDRIVE=YES
       DBLTIME=000000  to   DBLTIME=000100
       Until a fix is available from IBM
       for Apar OW03591 and OW03526.
    .
    ABEND50D RC08
       DB2/COBOL program writes to an existing sequential file with
       DISP=MOD.  When the sequential file reaches 16 extents on the
       DASD volume, Stop-X37, intercepts the B-37 abend and modifies
       the file to be multi-volume.  The DB2/COBOL program continues
       to execute and experiences the abend50D-08 when trying to
       close the file.   Essential Software was issuing a second
       OPEN J for the same exact ACB, which caused an exclusive
       enqueue on the TIOT, resulting in the ABEND50D-08.
       Essential Software provided the following zap ID:
       X3735P54 with a co-req of X3735P44 for Stop-X37 release 3.5.2
    .
    FSC0212 0212 have been caused by
    BMC CopyPlus for DB2, PDSFAST & RADAR
    WSC Flash 9408 G023361 explains how to find the application in
    error.
    .
    ABEND413 RC0C running ABARS ABACKUP on the D file that spans
    more than 1 tape volume.
    The problem was caused by OEM vendor that had hooks in EOV
    module IFG0552B.  Vendor was CA, the fix was TMD6999.
    If customers are experiencing this problem scenario, they
    should contact CA for the latest fix.  See also OY63369 and
    II07979.
    .
    HSM RECALL intermittently fails with:
    MSGARC0003I ARCRSTR1 TASK ABENDED, CODE 80FCF000 IN MODULE
                UNKNOWN, OFFSET 0000, STORAGE LOCATION 80FF3BB8
    IEAVESVC abends after an SVC CF (SVC207 x'SVCCF') from the
    patch area of IFG0194F.  CA's TMS was not properly initialized
    therefore MVS did not know about the svc.  This failure can
    occur for other tape jobs, not just HSM.  If this problem is
    encountered, reinitialize CA's TMS.
    .
    IEC029I (msgIEC029I) ABEND937 RC30 IFG0554E
        ABEND937-30 occurred on concatenation of the 2nd data set
        member using IEBGENER with the RACF bit on.  The problem was
        with CA's security package.  Inconsistent RACROUTE return
        codes were being passed back to OPEN from the SAF router.
        CA provided customer with a fix which resolved the problem.
        The CA fix number is TA1583B.
    .
    Nonterminating LOOP with SYSIN DD DUMMY
      Jobs were looping in ICVDSD03 at offset x'F2A' on TAPE input &
      DASD output with SYSIN DD DUMMY. The jobs could not cancel and
      had to be forced to terminate the loop. The problem was caused
      by an OBTAIN being issued from PWLFDSN, csect of LMOD MZ1CSPZP
      which is part of product CHANGE ACTION, put out by MAZDA Corp.
    .
    ABEND0C4 in IEWBIND modules ( IEWBXISI ) when using Computer
    Associates LIBRARIAN product with IBM BINDER product 5695DF108
    Fixes include GO32515 - GO27658
    MSA   08/12/94
    *
    MSGIEW2503S issued from modules produced on systems
    using CA-OPTIMIZER. IF AMBLIST LISTOBJ is issued against
    the same module an ABEND0C4 occurs.
    CA Fixes GO32991 and CO94791
    AER 8/24/94
    .
    SMFTYPE42 (SMF42) SUBTYPE6 S42JDRSD INVALID CENTURY FIELD
       Customer was seeing invalid S42JDRSD "date" record fields in
       the SMF TYPE 42 SUBTYPE 6.  The problem was caused by OEM
       scheduling package, CA7, who uses a reserved bit in the
       JCTRDTON of the JMR to identify jobs that it has submitted.
       The alteration of JCTRDTON by CA7 would normally cause the
       century field to be incorrect in all SMF records produced
       after the job has been processed by the INTRDR.
       CA7 provided fix # S3315.
    *
    ABEND806 RC2C RSN2704043E for PDSE
    ABEND806 RC08 IO ERROR on directory of PDS for a BLDL request
    This occurs while running with STK ICEBERG
    Fix: R01.00.06 CFT912 has fixed both errors.
    MSA 8/23/94
    *
    MSGWER999A RC021W from SYNCSORT
    Job that uses the same DCB for OUTPUT and then INPUT could get
    MSGWER999A RC021W from SYNCSORT.  This is caused by an OPEN J
    (OPENJ) for the INPUT DCB that modifies the JFCBVOLS and does
    NOT update the JFCBNVOL. This happens after OY66883 or OW00142
    or OW00361 (depending on the DFP release) because we were
    previously recalculating the JFCBNVOL in error.
    Contact SYNCSORT for EW4499 for Rel3.4 or Rel3.5 prior to the
    3.5E/TPF4A level.
                                                08/22/94 JBV/RHK
    .
    WILD BRANCH INTO ISTOCCO (VTAM) FROM IFG019RA
    Customer running HSM and FEOV was issued from ARCMSGS.
    Trace entry showed SVC DD to ACF2 from IFG019RA.  The next
    entry was a return back to ACF2 (ACF9E9RA+X'100) and then
    the wild branch to ISTOCCO.
    Problem attributed to Legent's tape management package
    EPIC/MVS. For externally managed datasets, EDMs, EPIC was
    returning to the OPEN path vs EOV.  This caused confusion in
    the ACF2 intercepts and thus the loop.
    (Fix number was not available)              JBV 08/29/94
    
    .
    MSGIOS000I COMMAND REJECT on a Locate Record X'47'
     Locate Record was being built by OEM product M204
     with an invalid data area containing 1 in bit 3
     Byte 0.  Fix is EW055 from vendor.   LAB 09/20/94
    .
    MSGIEC145I ABEND413 RC34 WITH VOLREF
       BMC utility job does image copy with 16 steps using referback
       processing.  When it comes to the 16th step, IEC145I 413-34
       is received with a volser specified.  BMC PTF # is P222617.
       An additional symptom of this problem is msgIEF245I.
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • close for Internet viewing
    

APAR Information

  • APAR number

    II07757

  • Reported component name

    V2 LIB INFO ITE

  • Reported component ID

    INFOV2LIB

  • Reported release

    001

  • Status

    CLOSED CAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    1994-04-04

  • Closed date

    1997-11-07

  • Last modified date

    2003-06-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
14 December 2020