APAR status
Closed as canceled.
Error description
LOOP OCCURS IN CSVRBENQ IN CONJUNCTION WITH AN ABEND106 RC0C OUT OF STORAGE FOR MODULE IBM0LMSU. TWO CUSTOMERS WHO EXPERIENCED THIS LOOP WERE AT CSVRBENQ WITH RMID/FMID HBB4430, ALTHOUGH IT COULD BE ANY LEVEL OF CSVRBENQ. THE LOOPING OFFSETS WERE X'6C' AND X'242'. IT IS A BRANCH ENTERED GETMAIN/FREEMAIN LOOP FOR SP253 FOR LENGTH OF X'1400'. SYSTEM TRACE EXAMPLE: 02 00B4 007FD360 SSRV 78 81111E1A 0000FD03 00001400 007B3C00 00B40000 02 00B4 007FD360 SSRV 78 81111C44 0000FD12 00001400 007B3C00 00B40000 02 00B4 007FD360 SSRV 78 81111E1A 0000FD03 00001400 007B3C00 00B40000 02 00B4 007FD360 SSRV 78 81111C44 0000FD12 00001400 007B3C00 00B40000 02 00B4 007FD360 SSRV 78 81111E1A 0000FD03 00001400 007B3C00 00B40000 02 00B4 007FD360 SSRV 78 81111C44 0000FD12 00001400 007B3C00 00B40000 THE ABEND106 RC0C WAS ACCOMPANIED BY THE FOLLOWING MESSAGES: CSV011I FETCH FAILED FOR MODULE IBM0LMSU, RETURN CODE 0C, REASON CODE 14 CSV028I ABEND106-0C JOBNAME=XXXXXXXX STEPNAME=X . THIS PROBLEM IS ADDRESSED BY COMMON LIBRARY APAR PN50483.
Local fix
ADDITIONAL COMMENTS: ONE CUSTOMER'S PROBLEM RECORD CONTAINED THE FOLLOWING UPDATE: "Found a job had been running for several hours. The job was using HSSR (IMS utility). Attempted to CANCEL it but no success. Attempted FORCE,ARM but no success. Job appeared to be in a CPU loop, and was affecting performance of the system. Took an SVC dump of the job, and got a partial dump. TRACE in the dump showed PSW for the address space in NUCLEUS module CSVRBENQ with many entries for offsets +6C and +242. Pressed RESTART key on hardware console, and replied ABEND to the resultant IEE107I and IEA500A messages. A system dump was taken and the job ended with a 222 abend."
Problem summary
Problem conclusion
Temporary fix
Comments
SEE APAR PN50483
APAR Information
APAR number
II07549
Reported component name
V2 LIB INFO ITE
Reported component ID
INFOV2LIB
Reported release
001
Status
CLOSED CAN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
1994-01-27
Closed date
1994-01-27
Last modified date
1994-01-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
14 December 2020