IBM Support

II07382: ABEND0C4 IN IEEMB848+X'DA'

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • INTRAN

Error description

  • 1. Abend0c4 in IEEMB848+x'DA' scanning through DSABs running
    past the end of the chain.  The number of DSABs was passed
       from IEFDB4F9, which determined the number from the TCT
       Lookup Table.  The TCT Lookup Table contained 9 duplicate
       entries that were not part of the free or allocated TIOT
       entries.  The problem was an OEM incorrectly modified the
       TCT Lookup Table causing the corruption.
    2. Abend0C4 in IEEMB848+x'F6'.  There were no duplicate TCTIOT
       (TCTTIOT) I/O Lookup Table entries, but the count of Lookup
       Table entries was not equal to the DSAB count.
    Additional Symptoms:
    1. OEM issued the following message prior to the abend:
       RECOVERY TERMINATED: DATASET EXISTS ON MAX VOLUMES
       Following this message was abend symptom dump message for
       abendb37-4 (rc4)
    2. OEM issued a message indicating a volume switch was being
       performed.
    

Local fix

  • See scratch pad for OEM fix information.
    

Problem summary

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    II07382

  • Reported component name

    V2 LIB INFO ITE

  • Reported component ID

    INFOV2LIB

  • Reported release

    001

  • Status

    INTRAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    1993-11-12

  • Closed date

  • Last modified date

    1994-09-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: