Error description

  • The purpose of this INFO APAR is to document HCD USAGE
    situations and the EXTERNAL SYMPTOMS for SEARCHABILITY by HCD
    support groups (i.e.,Level1,Level2).
    **** see INFO APAR II08750 for more info ****
    ****************************************************************
    D/T3995 model 15x. The model 15x emulates a 3390 and should be
    defined in HCD as a 3390 attached to a 3990 CU. For model 13x
    see II06097.
    ****************************************************************
    When attempting to use GRS w/an MVS 420 system using an ESCON
    channel, HCD/MVS will NOT accept BCTC on the 420 system.
    For this case gen the chpid type as CTC on the lpar
    that is higher than MVS 420 and use BCTC for the IODEVICE.
    On the lpar that is MVS 4.2 gen the chpid type as CNC.
    On this 420 system the device type should be CTC, not BCTC.
    Note:  The BCTC MUST be attached to the CTC side of the
    chpid in order for this method to function.
    ****************************************************************
    MSGCBDA107I EC LEVEL xxxxxx INVALID may be issued. The EC level
    parameter is ONLY required if there exists more than one SUPPORT
    LEVEL for the same PROCESSOR type. HCD then uses this parameter
    to select the correct SUPPORT LEVEL for the PROCESSOR type. The
    EC LEVEL associated with the PROCESSOR SUPPORT LEVEL for HCD can
    be obtained by the LIST SUPPORTED PROCESSOR panel in HCD dialog.
    ****************************************************************
    A D/T3172-3 ( model 3) attached to an ESCON CHPID should be
    defined to HCD in the CONTROL UNIT and DEVICE panels as
    UNIT=SCTC . 3172  D/T3172
    If APAR OY67361 is applied, code the 3172 as a 3172.
    ****************************************************************
    If devices are DELETED, HCD will automatically delete them from
    the ESOTERIC LIST. So, to change already existing NON-ESCON
    devices to ESCON devices, you only have to DISCONNECT them from
    the CONTROL UNITS they are defined to. Then, you can change the
    CONTROL UNIT definitions and RECONNECT the devices to the
    changed CONTROL UNITS. Using this procedure, the ESOTERIC LIST
    will stay unchanged.
    ****************************************************************
    Abend00f 990106 0990106 106 could occur if a backleveled of
    HCD panels are being used, ie. R201 panels on a R301 system.
    Refer to installation informational apar II05254 for
    installation information.
    Abend will also result if incorrect CLIST is being used,
     ie. HCD R3 uses NEWAPPL(HCD) R5 will use NEWAPPL(CBD).
     In this case check to see if another CLIST may be
    concatenated ahead of SYS1.SCBDCLST.
    ***********************************************************
    WAIT078 IEC331I at IPL time.  DFP 3.2 does not support
    devices that are defined with DYNAMIC=YES.
    additional symptom:
    Message ikj58508i w/dair 6704 (msgIKJ58508I rc6704 dair6704)
    may be seen to indicate DFP3.2 cannot handle Dynamic UCBs.
    (dynamic activate)
    DEVSERV command does not show that the dynamic devices exist.
    ***********************************************************
    ABEND00F RC 0990406 990406 check to see if IODF is truncated
    abend has been since for CBDMRRET and CBDMRMIG.  The
    cause of truncation was not determined.
    ************************************************************
    ****************************************************************
    IEW0731 MSGIEW0731 after apply of UY91054 on CBDP0032 and
    CBDP0033.  This message is issued because HCD used the same
    alias and member name.  This message can be ignored and
    development has agreed to no longer use the same alias.
    ****************************************************************
    When MIGRATING an MVSCP deck in BATCH (with an invalid IODEVICE
    statement), error message MSGCBDG080I 'NO EDT DEFINED' is
    issued after the 'PARM='PRODIODF' STEP is executed. This
    message is validly issued. The first error (in the
    'PARM='MIGR' step) is shown in the '.MESSAGES' DATA SET as
    documented in the HCD USER's GUIDE on page 8.19 where the
    MIGRATION LOG is discussed.
    ****************************************************************
    When using the HCD Processor List panel to "overtype" a
    processor model the following msg may appear:
     CBDA105I This processor type-model is not supported by the
      specified support level.
    .
    Use the 'c' (change) option to change the processor model for
    this case.
    ****************************************************************
    IOS445I MSGIOS445I Physical Device is inconsistent with logical
    definition for a CISCO router.  Router was defined as a 3088
    definition was changed to RS6K to correct the problem.
    ****************************************************************
    For diagnosis of a WAIT0B1 , any reason code, see module
    IEAIPL43 . If messages are not issued on the CONSOLE, they
    will be in the MODULE's virtual storage. REG 12 will point to
    the beginning of the module.
    IEAIPL43 may also call IOSIOFR to read the IODF file. IOSIOFR
    can also issue the WAIT0B1 RC01 if it cannot find the IODF.
    One reason for a RC01 is if a customer appends a low-level
    qualifier to the IODF name (i.e. sys1.iodf00.data). To
    correct the situation use the IDCAMS ALTER facility.
    ****************************************************************
    IEV044 **Error** Undefined Symbol may be issued after migrating
    an HCPRIO deck using HCD if an END statement is included in
    the HCPRIO deck. This also can occur if there is an END
    statement in the input IOCP deck. MSGIEV044.
    ASMA044E may also be issued depending on which level of
    assembler is being used.
    ****************************************************************
    MSGIOS500I Reason=0167 167 0167 CCM could not enter
               configuration mode
               DESCTEXT = Dynamic I/O configuration capability
               disabled, POR required
    Check to see if the Allow Modification and Percent Expansion
    options are selected on the processor.
    1) On the 9021 these can be found on the CONFIG frame 2 of 2.
    2) On the 9221 these can be found in the profiles.
    .
    Note that the percent expansion may only be changed at POR time
    but the Allow modification may be selected before or after POR.
    ***************************************************************
    When Viewing a Control Unit using HCD the PROTOCL value can
    be viewed by using HRIGHT on panel CBDPCU32
    ***************************************************************
    When migrating an IOCP deck to HCD, HCD will not accept a
    CNTLUNIT statement with UNIT=CTC and PROTOCL of S or S4.  If
    the CTC or CTC-like control unit supports S or S4, then
    UNIT=3088 should be specified on the CNTLUNIT statement.
    ***************************************************************
    unpredicable results can occur if a PROGRAM invokes DYNAMIC
    ALLLOCATION and uses OLD macro's (i.e. IOSLOOK) instead of the
    UCBLOOK macro to obtain UCB data. This would ONLY occur if the
    devices were gen'd as DYNAMIC instead of STATIC via the HCD
    PANELS. Until the program can be changed, the STATIC parameter
    must be used.
    ****************************************************************
    CBDA563I 'Space exhausted in work IODF xxxx'  followed by
    CBDA099I 'Internal logic error detected in module CBDMS
    Reason code = 153, error info = 00000008 0000000F 20530000 PMVS
    
    ****************************************************************
    When using an OS Group change the generic and certain device
    features may change for the entire group of devices that is
    being changed, use this with discretion.
    ****************************************************************
    HCD UDT's CBDES000 - CBDES256 ) need to be instaled in
    SYS1.NUCLEUS
    ****************************************************************
    D/T3898 and D/T3897 should be gen'd using HCD as
    CNTLUNIT UNIT=3088 and IODEVICE UNIT=CTC
    ****************************************************************
    WAIT031 UCB for SYSRES device not found.  Using procedure in
    OW01978 make sure that:
    1) Correct Loadxx memeber is used.
    2) Correct IODF is used.
    3) Correct OS is used.
    4) Using the above IODF make sure that SYSRES device is
       connected to an OS.
    5) Check for MSG IEA521I UIM not found in MQE's, if this is
       the case install the correct UIM in SYS1.NUCLEUS.
    *********************************************************
    Informational message MSGCBDG084I will be issued if a
    DUMMY is coded for the CONTROL UNIT 'type' and the
    PROTOCOL is coded as 'D'.
    This is an informational message only. The UIM
    (CBDUS050) has been designed to allow for the highest
    possible protocol. The highest protocol that the
    CONTROL UNIT can handle should be coded.
    ******************************************************
    MSGCBDA107I CBDA107I EC-Level is not valid for 3090 600J
    when using EC-Level 227578 for a 3090 600J.
    In this case EC-Level 227574 should be coded.
    ********************************************************
    If migrating to HCD on a D/T4381 and using a D/T3205 as
    the NIP or MASTER CONSOLE and have UNIT = LCA coded in
    the CONTROL UNIT MACRO, HCD error message MSGCBDA234I
    UNKNOWN TYPE LCA will be issued. The resolution is to
    code UNIT = 3274 instead of LCA. There is no UIM that
    allows LCA and this is the reason HCD issues this message.
    **********************************************************
    When attempting to install HCD via CBIPO MSGCBDA046I
    CBDA046I may occur.  This msg may be ignored however since
    the COND statement of the EXEC in the CBIPO step contains
    COND=(0,NE) this will cause subsequent steps to be flushed.
    Change the cond parm so that the CBIPO init step will run
    even if a RC=4 is received.
    Also INIT step of the CBIPO job may fail due to a cond of 4 and
    IEC161 72-053.  Since this step failed the .cluster data set for
    te PROD step was never created, thus the production step failed
    Wth CBDA469I RC8 RSN28.  Change the cond on the INIT stop and
    Change the cond on the INIT step and re-run the PROD step.
    .
    ***************************************************************
    When defining an OEM DASD device ( ie. ICEBERG ) as a 3990
    if a model is used on the control unit
     CBDA299I MSGCBDA299I Control unit xxx has more than max number
     of devices attached
    is rec'd.  In this case the model parameter should not be used.
    If the model parameter is not used the UIM allows up to 256
    devices to be attached.
    MSGCBDA299I may also be issued when defining
    256 devices for 9393 X83 if the model is specified
    on the CNTLUNIT definition TYPE= parameter.
    Removing the model from the CNTLUNIT definition
    resolves the problem.
    
    ***********************************************************
    ISPP100 panel CBDCxxx not found when accessing HCD help
    panels.  ie, CBDC099 when using HCD R501 under MVS 4.3
    Problem here is that user has an old R301 clist
    concatenated ahead of SYS1.SCBDCLST.
    ***********************************************************
    MSGCBDA125I issued when using the TRACE command in the
    HCD PROFILE dataset and this dataset is 'sequenced'.
    The 'sequence' number is shown in this error message.
    To resolve this problem, set NUMBER OFF from ISPF when
    editing this dataset.
    ************************************************************
    CBDA153I  MSGCBDA153I Channel path ID 00 already exists.
     when chpid 00 id not in the migration input deck.
    Check to see that the correct MACLIB is being used.
    *************************************************************
    WAIT0B1 RC 006 6 when IPL'ing from an IODF generated after
    running the CBIPO dialogs and using the copy function.
    Ensure that the OS and EDT in the LOADxx member correspond
    to the OS and EDT in the IODF that was used as the source
    of the copy.  If the LOADxx member contains CBIPO as the
    OS and the source of the copy contains a different OS id
    this would cause a WAIT0B1 RC 0006
    *************************************************************
    
    MSGCBDA268I CBDA268I No Control Unit Information Table found
    for DEV# issued during CBIPO install or when running HCD dialog
    or batch.  This message is issued when HCD cannot find the
    UIM(s) in SYS1.NUCLEUS.  If the user has the UIM(s) in a
    library other than SYS1.NUCLEUS a HCDPROF DD statement is
    required with UIM_LIBNAME=library that contains UIMs and
    UIM_VOLSER=volser of library.  See HCD Users Guide (SC33-6468)
    chapters 2 & 12 for more information.
    **************************************************************
    If you are using HCD on a system with a DFP level that is
    higher than the one being IPL'd the following msg's may be
    surfaced to the user at IPL time or when using HCD:
    MSGCBDA381I PARAMETER 33 or 34 FOR DEVICE xxx NOT FOUND IN UDT
                CBDES005 .
    This msg is issued during IPL of MVS or using HCD due MISMATCH
    in PTF levels of module CBDES005. If 'TAPE LIBRARY SUPPORT' or
    'AUTOSWITCH (D/T3495) is not used, these msgs can be ignored.
    To eliminate the message for parameter 33, CBDES005 must be at
    ptf level UW01274 for DFP 3.3 (APAR is OW00644).
     To eliminate the message for parameter 34 CBDES005 must
    be at ptf level UW20584 for DFP 3.3 (APAR is OW14622).
    ************************************************************
    MSGCBDG300I - Insufficient authority to process the request.
    On the HCD ADD PROCESSOR panel if you do not have RACF or
    another security package installed, you must leave the
    'Network name' and 'CPC name' fields blank. If they are
    not blank you will receive MSCBDG300I and the job will
    cancel when you run the iocp job to create the IOCDS.
    CBDG300I
    ********************************************************
    MSGCBDA560I CBDA560I - If the HCD migration log and the
    .LISTING file do not have any information as to which
    statement is in error check the level of module CBDZPARS in
    SYS1.MACLIB. The customer may be running with an HCSH301
    version. If running HCD V5.1, the module should be at
    HCSH501.
    ***********************************************************
    HCD AND COUPLING FACILITY ( CF ) PARTITION 9672
    ICMF MSGCBDG401I and 9121 511-based
    *
    HCD will not allow a CF partition to be defined on these
    processors, only allows OS type partitions.  CF channels are
    not supported by hardware.. But ICMF can be run in a
    partition, simulating coupling facility functions.
    .
    If you attempt to define a 'CF' partition on the 'ADD PARTITION'
    panel in HCD, you will receive the following message:
    'CBDG401I Usage type CF specified for partition XXX is not
     supported by processor'
    *
    There is no reason to define a partition as CF in HCD if
    CF channels are not supported on the hardware.
    ICMF can be run in an OS partition which is defined in HCD.
    At POR the partition is defined as a CF to the hardware.
    You may get a warning message when you do this:
    CBDA857I NO CHANNEL PATHS ATTACHED TO PARTITION.
    This message may be ignored.
    On the processor, you must turn on ICMF for the partition.
    Choose CF then ICMF.
    ****************************************************************
    When attemping to migrate extended user parmameter's ( USERPRM )
    on the IODEVICE macro use only the UIM Private Parameter's as
    documented in the HCD User's Guide.  DYNAMIC and LOCANY are
    NOT private parameter's.  If DYNAMIC and LOCANY are to be set
    specify:
      IODEVICE UNIT=3380,ADDRESS=(520,32),CUNUMBR=(050,150),
           FEATURE=(SHARED,ALTCTRL),DYNAMIC=YES,LOCANY=YES
    KEYWORDS:
     MSGCBDA857I MSCBDA857I 9672 MSCBDG401I
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • cancelled as info apar.
    

APAR Information

  • APAR number

    II07348

  • Reported component name

    V2 LIB INFO ITE

  • Reported component ID

    INFOV2LIB

  • Reported release

    001

  • Status

    CLOSED CAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1993-10-26

  • Closed date

    1993-10-26

  • Last modified date

    2000-10-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
14 December 2020