Error description
RMF Channel Path reports, Utilization values: When RMF cannot collect channel path data, it reports dashes for these paths. The channel paths in question are listed below. Channel Path | Acronym | Description --------------+---------------------------- BYTE | Parallel Byte Multiplex CBY | ESCON Path to a Byte Converter ISD | Internal System Device DSD | Direct System Device EIO | Emulated I/O CFS | Coupling Facility Sender CFR | Coupling Facility Receiver CBS | Cluster Bus Sender CBR | Cluster Bus Receiver ICS | Internal Coupling Sender ICR | Internal Coupling Receiver CBP | Integrated Cluster Bus Peer CFP | Coupling Facility Peer CIB | Coupling links using InfiniBand ICP | Internal Coupling Peer To collect Channel Path data, RMF inspects SRM maintained control blocks at the end of each measurement interval. Due to hardware restrictions (which are processor type dependent), these data may be not, or only partially, available to SRM. When the data is not available for a Coupling Facility Path, the average utilization for the set of CF links from a system to a CF may be calculated with the data in the RMF Coupling Facility Report, Subchannel Activity Section. ((SYNC #REQ * SYNC service time) + (ASYNC #REQ * ASYNC service time)) Utilization % = --------------------------------------- * 100 Interval time * #subchannels in use
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
II05151
Reported component name
V2 LIB INFO ITE
Reported component ID
INFOV2LIB
Reported release
001
Status
CLOSED CAN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
1991-06-18
Closed date
1993-10-22
Last modified date
2008-10-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
13 December 2020