Error description

  • RUNNING THE NIGHTLY BATCH MAINTENANCE JOB RECEIVED A U=0476
    ERROR MESSAGE AGAINST MODULE FAHUQMT.  U=0476 SUGGESTS A PCB
    ADDRESS PROBLEM.  I OBTAINED A COPY OF THE PSBGEN FROM THE
    CUSTOMER AND ALSO OBTAINED A COMPILE LISTING OF THE MODULE
    FAHUQMT.  I COMPARED THE PCS'S IN THE PSB WITH THE PCB'S IN THE
    "ENTRY 'DLITCBL' USING", AFTER THE PROCEDURE DIVISION, IN THE
    PROGRAM.  I NOTICED A MISMATCH. CALLED THE CHANGE TEAM AND FOUND
    THAT THEY WERE RUNNING WITH THE PRE-GA PSB.  THEY SHOULD HAVE
    BEEN RUNNING WITH THE PSB THAT WAS SHIPPED WITH PTF UL45260.
    

Local fix

  • RAN WITH CORRECT PSB - PROBLEM SOLVED.
    

Problem summary

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    II04456

  • Reported component name

    PA LIB INFO ITE

  • Reported component ID

    INFOPALIB

  • Reported release

    001

  • Status

    CLOSED CAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1990-06-04

  • Closed date

    1990-09-17

  • Last modified date

    1990-09-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG32M","label":"APARs - VSE\/ESA environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG27M","label":"APARs - z\/VM environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB16","label":"Mainframe HW"}}]

Document Information

Modified date:
13 December 2020