Error description

  • CICS AUTOINSTALL FAILURE WITH MESSAGE DFH5923 AFTER
    APPLICATION OF PL16388 CUSTOMERS MAY ENCOUNTER AUTOINSTALL
    FAILURES INDICATED BY MSGDFH5923I OR MSGDFH2411I (MSGDFH2411).
    
    AFTER APPLICATION OF PL16388, WHEN THE SEND AND/OR RECEIVE RU
    SIZES ARE SPECIFIED IN THE TYPETERM ENTRY, IF THE RU SIZES ARE
    ALSO SPECIFIED IN THE LOGMODE TABLE ENTRY THEY MUST BE LESS THAN
    THE VALUE SPECIFIED IN THE TYPETERM.
    
    
    FOR EXAMPLE, IF YOU CODE A RECEIVE RU SIZE OF 256 IN THE
    TYPETERM BUT HAVE 1024 CODED IN THE LOGMODE TABLE ENTRY, THE
    INSTALL REQUEST WILL FAIL WITH A MESSAGE DFH5923 GIVEN.
    
    TO VERIFY THIS CONDITION YOU MUST COMPARE THE LOGMODE TABLE
    DATA WITH THE CICS DATA FOUND IN THE MODEL ENTRY ON THE
    RESTART DATA SET. THE RSD MAY BE PRINTED USING AMSPRINT. THE
    MODEL ENTRIES ARE IDENTIFIED BY THE CHARACTERS TORMM, (CONSULT
    THE CADL MESSAGE LOG FOR THE MODEL BEING USED FOR THE
    INSTALL). THE BIND IMAGE IS FOUND AT THE END OF THE MODEL IN
    QUESTION.
    
    IF THE LOGMODE ENTRY INFORMATION IS NOT AVAILABLE, YOU MAY
    OBTAIN THE BIND INFORMATION FROM THE CINIT RU. THE CINIT RU
    CAN BE FOUND IN A VTAM BUFFER TRACE DURING THE AUTOINSTALL
    REQUEST.
    
    ONCE YOU HAVE THE CINIT BIND AND THE MODEL BIND, THE BYTES WHICH
    ARE CHECKED ARE FOUND AT OFFSET 10 AND 11 (DECIMAL). OFFSET
    10 IS THE RECEIVE RU SIZE AND 11 IS THE SEND RU SIZE. IN THE
    EXAMPLE THE MODEL BIND WILL HAVE AN X'85' AT OFFSET 10 WHILE
    THE CINIT BIND WILL HAVE AN X 87' AT OFFSET 10. SINCE THE
    CINIT VALUE IS LARGER THAN THE MODEL SIZE THE INSTALL REQUEST
    WILL TERMINATED WITH A MESSAGE DFH5923. FOR AN AUTOINSTALLED
    TERMINAL, SPECIFYING A NON-ZERO RECEIVESIZE/SENDSIZE WILL
    INDICATE TO CICS WHAT THE MAXIMUM OR ACTUAL VALUE OF THE
    RECEIVE/SEND RUSIZE MAY BE. IF THE APPROPRIATE RUSIZE WITHIN
    THE CINIT BIND IMAGE (SPECIFIED IN THE VTAM LOGMODE ENTRY) HAS
    A NON-ZERO VALUE THEN THE TYPETERM RECEIVESIZE/SENDSIZE WILL
    BE USED TO INDICATE THE MAXIMUM VALUE.
    
    HOWEVER: IF THE APPROPRIATE RUSIZE WITHIN THE CINIT BIND IMAGE
    IS ZERO THEN THE TYPETERM RECEIVESIZE/SENDSIZE WILL BE USED.
    
    THE FOLLOWING EXAMPLES DESCRIBE THE RESULTING BIND RECEIVE
    RUSIZES FROM A SET OF INPUT CINIT RUSIZES AND TYPETERM
    RECEIVESIZE. (THE SAME RULES APPLY TO THE SEND RUSIZE AND
    TYPETERM SENDSIZE).
    
    THE CINIT BIND RUSIZE (FROM LOGMODE TABLE) IS GREATER THAN
    ZERO BUT LESS THAN THE TYPETERM RECEIVESIZE, CICS USES THE
    CINIT RUSIZE.
    
    THE CINIT SIZE IS GREATER THAN ZERO AND IS GREATER THAN THE
    TYPETERM RECEIVESIZE (WHICH IS GREATER THAN ZERO), CICS WILL
    REJECT THE LOGON WITH MSGDFH5923.
    
    THE CINIT SIZE IS GREATER THAN ZERO AND THE TYPETERM
    RECEIVESIZE IS ZERO, CICS USES THE CINIT RUSIZE.
    
    THE CINIT SIZE IS ZERO AND THE TYPETERM RECEIVESIZE IS
    GREATER THAN ZERO, CICS WILL USE THE RECEIVESIZE VALUE.
    
    THE CINIT SIZE IS ZERO AND THE TYPETERM RECEIVESIZE IS ZERO,
    THIS WILL RESULT IN A ZERO RUSIZE WHICH IS ONLY VALID FOR
    BISYNC DEVICES.
    
    PL21136 ADDRESSES A PROBLEM CAUSED WHEN THE RUSIZES ARE SET TO
    ZERO IN THE TYPETERM AND LOGMODE ENTRY. THE RESULTING BIND
    IMAGE CONTAINS X'40' IN BOTH THE SEND AND RECEIVE RUSIZE FOR
    NON-SNA TERMINALS.
    
    THE FIX FOR PL21136 "MUST" BE APPLIED WHEN NON-SNA
    TERMINALS ARE IN USE.  FOR BISYNC TERMINALS  RU SIZES MUST
    BE SET TO ZERO (00) IN THE TYPETERM AND LOGMODE TABLE ENTRIES.
    
    FAILURE TO SET THE RU SIZES TO ZERO MAY RESULT IN INTERMITTENT
    MSGDFH3424 ERROR MESSAGES.  MSGDFHZC3424 DFHZC3424
    
    THIS INFORMATION IS ALSO APPLICABLE TO APAR PL18595 FOR
    CICS MVS RELEASE 2.1 COMPID 566540301.
    FOR DOS, APAR IS PL18597.
    ADDED FOR SEARCHABILITY 5746XX300 RI69 RA69 RA71 R170
    MSGDFH5963 MSGDFH5963E
    ADDITIONAL KEYWORDS:
    566540301 R321 321 V321 CICS/ESA
    565501800 R410 410 R100 100
    565514700 R300 300 R530 530 R200 200 R520 520 R510 510
    5697E9300 R610 610 R620 620 R630 630
    MSGDFHZC5963 DFHZC5963 MSGDFHZC6903 DFHZC6903
    

Local fix

  • JIM GRAUEL
    CICS LEVEL 2
    RALEIGH
    

Problem summary

Problem conclusion

Temporary fix

Comments

  • INFORMATION APAR
    

APAR Information

  • APAR number

    II03226

  • Reported component name

    PB LIB INFO ITE

  • Reported component ID

    INFOPBLIB

  • Reported release

    001

  • Status

    CLOSED CAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1988-01-06

  • Closed date

    1988-01-06

  • Last modified date

    2004-09-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
13 December 2020