II02105: ENABLED WAIT AT IPL ON A D/T4381, NO-CONSOLES CONDITION, MSGIEA420A ISSUED BUT NOT SEEN, or MSGIEE129I MSGIEE870I

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as canceled.

Error description

  • ENABLED WAIT AT IPL TIME. NIP MESSAGES HAVE FINISHED WRITING TO
    THE MASTER CONSOLE AND THE NEXT MESSAGE OUT SHOULD BE PROCESSED
    BY COMTASK. THE ALARM SHOULD HAVE RUNG THREE TIMES INDICATING
    THAT A NO-CONSOLES CONDITION EXISTS. MSGIEA420A IS SEEN IN THE
    WQE BUFFERS IN A STANDALONE DUMP TAKEN AT THE TIME OF THE WAIT.
    THE MASTER CONSOLE IS A D/T3205 ON A D/T4381 CPU.
    *** Additional symptoms - MSGIEE129I or MSGIEE870I IOER
    IO ERROR after IPL when trying to vary on a console attached
    to the D/T4381 Preprocessor port.
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • THIS APAR WAS CREATED TO DOCUMENT PROBLEMS THAT RESULT
    IN A NO WORK WAIT, ENABLED WAIT ( 070E0000 00000000 ), DUMMY
    WAIT, AT IPL TIME.
    SUCH A WAIT AT IPL TIME USUALLY INDICATES THAT A NO-CONSOLES
    CONDITION EXISTS. WHEN THIS HAPPENS, THE ALARM WILL SOUND THREE
    TIMES. ALSO, MSGIEA420A WILL BE ISSUED TO INDICATE THE REASON
    FOR THE NO-CONSOLES CONDITION. IF A PRINTER CONSOLE IS ACTIVE,
    THIS MESSAGE WILL APPEAR THERE. OTHERWISE, THE MESSAGE WILL BE
    SEEN IN THE MASTER TRACE TABLE OR ON THE WQE CHAIN. THIS
    CONDITION CAN BE RECOVERABLE BY FOLLOWING THE PROCEEDURES ON THE
    MSGIEA420A OR IN THE SYSTEM COMMANDS MANUAL.
    THE MOST COMMON REASON FOR THE NO-CONSOLES CONDITION TO ARISE AT
    IPL TIME IS AN IOER. CHECK THE FOLLOWING:
    1. ON A D/T43XX CPU, CONSOLE DEVICES PLUGGED INTO THE
       PREPROCESSOR PORTS MUST BE GENNED AS A D/T3278-2A OR A
       D/T3279-2C.
    2. CONSOLE DEVICES PLUGGED INTO THE PREPROCESSOR PORTS CAN NOT
       HAVE THE PTREAD (PREPARE TO READ) FEATURE SPECIFIED ON THE
       IODEVICES MACRO. THIS WILL RESULT IN AN IOER ON A X'4B'
       OPCODE WHICH THE MICRO CODE IN THE PORTS DOES NOT UNDERSTAND.
    *** Additionally, after IPL a console switch for an IOER can
    result when trying to vary on a console that is attached to the
    preprocessor port.  The CONSOLxx parmlib member must specify
    these console devices as UNIT 3278-2A or 3279-2C.  They can not
    be specified as 3270-X.  Error message IEE129I will result on
    an MVS/ESA V3 system and IEE870I will result on an MVS/ESA V4
    system (HBB4410, HBB4420, JBB4422).
    

APAR Information

  • APAR number

    II02105

  • Reported component name

    V2 LIB INFO ITE

  • Reported component ID

    INFOV2LIB

  • Reported release

    001

  • Status

    CLOSED CAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    1985-07-02

  • Closed date

    1985-07-03

  • Last modified date

    1993-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
13 December 2020